EasyManua.ls Logo

WIKA PSD-30 - Operating Conditions

WIKA PSD-30
124 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13WIKA operating instructions pressure switch, model PSD-3x
EN
11430486.07 04/2015 EN/DE/FR/ES
3. Specications
3.7 Operating conditions
Permissible temperature ranges
Medium: -20 ... +85 °C (-4 ... +185 °F)
Ambient: -20 ... +80 °C (-4 ... +176 °F)
Storage: -20 ... +80 °C (-4 ... +176 °F)
Nominal temperature: 0 ... 80 °C (32 ... 176 °F)
Humidity
45 ... 75 % r. h.
Vibration resistance
10 g (IEC 60068-2-6, under resonance)
Shock resistance
50 g (IEC 60068-2-27, mechanical)
Service life, mechanics
100 million load cycles (10 million load cycles for measuring ranges > 600 bar/7,500 psi)
Ingress protection
IP 65 and IP 67
The stated ingress protection (per IEC 60529) only applies when plugged in using mating connectors
that have the appropriate ingress protection.
Mounting position
as required