Page 10 of 24 pages
Norsk
Model
Weight
Height Width Dept
Miro 1
79 kg 71.2 cm 46.8 cm 35.5 cm
Miro 1 on pedestal
90 kg 110.8 cm 46.8 cm 35.6 cm
Miro 2
82 kg 71.2 cm 46.8 cm 35.5 cm
Miro 2 on pedestall
93 kg 110.8 c m 46.8 cm 35.6 cm
Miro 3
93 kg 101.2 cm 46.8 cm 35.6 cm
Miro 4
93 kg 101.2 cm 46.8 cm 35.6 cm
Miro 4 with natural stone cladding
217 kg 104.4 cm 54.5 cm 35.6 cm
Miro 4 with tile cladding
130 kg 104.4 cm 54.5 cm 35.6 cm
Miro 5
94 kg 131.4 cm 46.8 cm 35.6 cm
Miro 6
97kg 131.4 cm 46.8 cm 35.6 cm
Miro 6 with natural stone cladding
252 kg 135.1 cm 54.5 cm 35.6 cm
Miro 6 with tile cladding
143 kg 135.1 cm 54.5 cm 35.6 cm
Heat storage stones, Miro 5+6
34 kg
Floor plate
European, national and local regulations must be observed in terms of the size and thickness
your WIKING retailer for assistance. The combustion chamber opening is 35,2 cm wide.
Distance to combustible materials
Min. distances
- uninsulated ue gas pipe:
Miro 1
Miro 3
Miro 5
Miro 2
Miro 4
Miro 6
Miro 4 med
stone-/ tile cladding
Miro 6 med
stone-/ tile cladding
Recommended for brick wall, back
10 cm 10 cm 10 cm
Recommended for brick wall, side
15 cm 10 cm 10 cm
For combustible wall, back
10 cm 10 cm 10 cm
For combustible wall, side
52 cm 31 cm 31 cm
To combustible wall,
corner installation, 45º
38 cm 10 cm 10 cm
7* cm 7* cm
Distance to furnishings in front
90 cm 90 cm 90 cm
* Applies only to WIKING Miro 1 and WIKING Miro 2. This distance requirement is observed when the wood-burning stove is mounted on a
pedestal or a wall with the required distance below the wood-burning stove.
Remember to pay attention to the applicable regulations concerning the required distance
between the wall and smoke pipe.
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should
sometimes be treated as a combustible wall, in which case we ask you to contact your local
chimney sweep or glass producer to hear at what distance the stove should be kept from glass.
Requirements for chimney and smoke pipe
As a general rule, satisfactory draught conditions are achieved if the chimney is 4 m above