REGULATORY INFORMATION AND INSTALLATION REQUIREMENTS
THE FOLLOWING MUST BE NOTED PRIOR TO THE INSTALLATION OF THIS APPLIANCE.
This gas appliance MUST be installed by a GAS SAFE registered installer by law. It must be installed in
accordance to these installaon instrucons and the GAS SAFETY (Installaon & Use) REGULATIONS 1998 as
amended. Non compliance of this law may lead to prosecuon and it is in the interest of you and your
family that this condion is observed.
The installaon of this appliance must be in accordance with the relevant parts of the LOCAL AND
NATIONAL BUILDING REGULATIONS as issued by the Department of the Environment or BUILDING
STANDARD (Scotland Consolidaon) REGULATIONS issued by the Scosh Development Department and
the following relevant Brish Standards:
BS5871 Part 2 Installaon of Inset Live Fuel Eect Gas Fires
BS5440 Parts 1 & 2 Installaon of Flues and Venlaon
BS6891 Installaon of Gas Pipe-work
BS6461 Part 1 Installaon of Chimneys and Flues
BS1251 Open Fireplace Components
BS715/BS EN 1856-2 Metal Flue Pipes for Gas Appliances
BS EN 1858 Chimneys Components & Concrete Flue Blocks
IS813:1996 Domesc Gas Installaon (Republic of Ireland)
Prior to installaon ensure that the gas supply is compable with the appliance, this appliance must only be
used on natural gas at a supply pressure of 20 mbar as marked on the data plate on the appliance and the
carton.
This appliance is only to be installed into a builder opening which must be constructed of non-combusble
materials conrming to BS1251 or a suitable ue-box complying with the requirements of BS715/BS EN
1856-2.
If the product is being installed into a builders opening the chimney must be at least 3 metres in height and
should be swept before installaon if it has been used for the burning of solid fuel (e.g. coal or wood). The
chimney must only serve as a ue-way to this appliance and must have no openings to any other room. The
opening should be inspected and any exposed brickwork should be repaired where necessary. The chair-
brick (if applicable) should be removed unless the minimum depth of the replace exceeds 175mm. If the
depth is less than 175mm then the chair brick MUST be removed.
If the product is being installed into a fabricated Flue-box it must be installed onto a non-combusble
surface with a thickness of at least 12mm.
This replace is also suitable for installaon into precast ue replaces which comply to the requirements
of BS EN1858. It is important to note that pre-cast ue systems should be constructed with an air gap or
some form of insulaon material between the ue block and the plastered face; pre-cast ue systems with
a plastered face directly in contact with the ue block are not correctly installed and installaon of this
appliance into such a ue system may result in the plaster cracking above the appliance. Flue-way must be
through a Class I (7” or 175mm diameter) or Class II (5” or 125mm diameter) ue of at least three meters in
height.
The ue should be checked for draw using a smoke bomb or similar, if there is a denite draw then the
installaon of the appliance can proceed.