No purpose made venlaon is normally required for this appliance when installed in G.B. If the appliance is
being installed in I.E then refer to I.S 813:1996 (Domesc Gas Installaon—Naonal Standards Authority of
Ireland). Venlaon areas (if applicable) should be checked periodically to ensure there is no obstrucon,
even though none is normally required for this appliance.
IMPORTANT NOTE: If the appliance being installed is an XE model then the XE restrictor supplied in the XE
FITTING PACK should be ed (Ensure the restrictor being ed states the model number F-021XXX). It is
mandatory that when ng the XE restrictor, that the XE CANOPY also must be ed. When installing the
XE restrictor onto an appliance where the ue is 7” (or 9” brick chimney) and of a minimum height of at least
5 metres, the addional restrictor (supplied in the XE pack also) can also be ed for addional eciency.
It is mandatory that the safe clearance of products be checked by performing a smoke match test as
described on the product data label.
SPILLAGE TEST: To check for sasfactory clearance of products of combuson, close all doors and windows
and leave the appliance burning on HIGH for ve minutes. Insert a lit smoke match just into the top of the
re opening and move it le and right, all the smoke must be drawn into the ue. If spillage occurs allow a
further 5 minutes and repeat the test. If spillage sll occurs turn o the appliance and seek expert advise . If
an extractor fan is situated in the room the spillage test should be repeated with the fan running. If there is a
connecng room with an extractor fan the test should be repeated with all the doors to that room open and
the extractor fan running. If the appliance spills with the restrictor ed then the restrictor should be
removed and the spillage test repeated. If the spillage test connues to fail expert advise should be sought
and addional venlaon may have to be provided.
This appliance must only be installed on to a suitable hearth with a minimum thickness of 12mm. The
appliance must not be installed directly onto carpet of other combusble oor materials. The replace
surround (back-panel) must have a temperature rang of at least 150
o
C.
Do not place so wall coverings (i.e. embossed papers etc,) furniture or other combusble items too close to
the res as they may discolour or scorch.
Do not place or throw rubbish or otherwise on the fuel-bed.
Do not place any combusble materials or ooring (i.e. carpets etc,) on any part of the hearth.
WARNING: This appliance has a naked ame and as with all heang appliances a reguard should be used
for the protecon of children, the elderly and inrm. The reguard should conform to BS8423 : 2002
(Fireguards or use with Gas Heang Appliances).
Important Note: It is quite normal for a ame eect gas appliance to experience a small amount of soot or
staining to some parts of the fuel eect components. If this becomes excessive it may because the fuel bed
is not ed correctly—this should be checked according to these installaon instrucons prior to
contacng a service engineer.
It is very important that you arrange for a GAS SAFE registered engineer to service your appliance every year
– during this service the engineer will remove the appliance and check for debris, check the operaon of the
ue and check the operaon of the appliance. This is important for you and your families safety.
NEVER place any rubbish or otherwise onto the re—this will aect the way the product operates and may
aect the warranty of the product.
NEVER place more ceramic components onto the fuel bed than specied in the instrucons.
NEVER touch the ceramics when the appliance has recently been switched o—these components retain
heat and may cause burns. Leave the appliance to suciently cool prior to any contact of the ceramics.