4
No purpose made venlaon is normally required for this appliance when installed in G.B. If the appliance is
being installed in I.E then refer to I.S 813:1996 (Domesc Gas Installaon—Naonal Standards Authority of
Ireland). Venlaon areas (if applicable) should be checked periodically to ensure there is no obstrucon,
even though none is normally required for this appliance.
IMPORTANT NOTE: If the appliance being installed is an XE model then the XE restrictor supplied in the XE
FITTING PACK should be ed (Ensure the restrictor being ed states the model number F-021XXX). It is
mandatory that when ng the XE restrictor, that the XE CANOPY also must be ed. When installing the
XE restrictor onto an appliance where the ue is 7” (or 9” brick chimney) and of a minimum height of at least
5 metres, the addional restrictor (supplied in the XE pack also) can also be ed for addional eciency.
It is mandatory that the safe clearance of products be checked by performing a smoke match test as
described on the product data label.
SPILLAGE TEST: To check for sasfactory clearance of products of combuson, close all doors and windows
and leave the appliance burning on HIGH for ve minutes. Insert a lit smoke match just into the top of the
re opening and move it le and right, all the smoke must be drawn into the ue. If spillage occurs allow a
further 5 minutes and repeat the test. If spillage sll occurs turn o the appliance and seek expert advise . If
an extractor fan is situated in the room the spillage test should be repeated with the fan running. If there is a
connecng room with an extractor fan the test should be repeated with all the doors to that room open and
the extractor fan running. If the appliance spills with the restrictor ed then the restrictor should be
removed and the spillage test repeated. If the spillage test connues to fail expert advise should be sought
and addional venlaon may have to be provided.
This appliance must only be installed on to a suitable hearth with a minimum thickness of 12mm. The
appliance must not be installed directly onto carpet of other combusble oor materials. The replace
surround (back-panel) must have a temperature rang of at least 150
o
C.
Do not place so wall coverings (i.e. embossed papers etc,) furniture or other combusble items too close to
the res as they may discolour or scorch.
Do not place or throw rubbish or otherwise on the fuel-bed.
Do not place any combusble materials or ooring (i.e. carpets etc,) on any part of the hearth.
WARNING: This appliance has a naked ame and as with all heang appliances a reguard should be used
for the protecon of children, the elderly and inrm. The reguard should conform to BS8423 : 2002
(Fireguards or use with Gas Heang Appliances).
Important Note: It is quite normal for a ame eect gas appliance to experience a small amount of soot or
staining to some parts of the fuel eect components. If this becomes excessive it may because the fuel bed
is not ed correctly—this should be checked according to these installaon instrucons prior to
contacng a service engineer.
It is very important that you arrange for a GAS SAFE registered engineer to service your appliance every year
– during this service the engineer will remove the appliance and check for debris, check the operaon of the
ue and check the operaon of the appliance. This is important for you and your families safety.
NEVER place any rubbish or otherwise onto the re—this will aect the way the product operates and may
aect the warranty of the product.
NEVER place more ceramic components onto the fuel bed than specied in the instrucons.
NEVER touch the ceramics when the appliance has recently been switched o—these components retain
heat and may cause burns. Leave the appliance to suciently cool prior to any contact of the ceramics.