How to stop beeping on Willhi Temperature Controller?
- Kkathryn75Jul 28, 2025
If the Willhi Temperature Controller unit keeps beeping at a certain temperature, the alarm function can be disabled. To do this, set “AH” to 230 and “AL” to -58.
How to stop beeping on Willhi Temperature Controller?
If the Willhi Temperature Controller unit keeps beeping at a certain temperature, the alarm function can be disabled. To do this, set “AH” to 230 and “AL” to -58.
What to do if Willhi Temperature Controller display shows dashes?
If the display of your Willhi Temperature Controller shows “---“ or some other malfunction occurs, restore the factory default settings. Power off the unit, then power it back on. While it's cycling through showing “888” and “---“, hold the SET and UP buttons for 10 seconds.
Why Willhi Temperature Controller displays EEE?
If the Willhi Temperature Controller displays EEE while beeping, the probe might not be fully inserted into the jack or it could be defective. Email service@bayite.com for a free probe replacement.
How to fix Willhi WH1436A Temperature Controller if the output device won’t power on?
If the output device won’t power on when using your Willhi Temperature Controller, check that both the controller and the output device are securely plugged in. Also, verify that the value for power on temperature “ON” is set correctly.
Model | WH1436A |
---|---|
Temperature Control Accuracy | ±1°C |
Output Type | Relay |
Display Type | LED |
Input Power | <3W |
Temperature Measuring Range | -50 to 110°C |
Temperature Control Range | -50 to 110°C |
Output Capacity | 10A |
Sensor | NTC |
Sensor Type | NTC10K |
Critical warnings about load limits, overloading, and fire hazards. Check power requirements before use.
Guidelines for safe connection, avoiding water, proper cord handling, and unit modification.
Procedures for responding to damage, smoke, odor, or noise, and when to consult a dealer.
Highlights include turning on/off at desired temperatures, saved settings, calibration, and alarms.
Details on max load, power supply, probe range, accuracy, working temperature, and plug type.
Explanation of POWER, SET, and UP/DOWN buttons for operation and menu navigation.
Description of the alarm feature, how to enable it, and how to silence it during operation.
Steps to set ON and OFF temperatures for heating or cooling applications.
Definitions for ON, OFF, CA, PT, AH, AL, and AT parameters with their default and range values.
Solutions for output not powering on, probe errors (EEE), range issues (LLL/HHH), and malfunctions.
Accessing and configuring CF (unit), ST (increment), dL (timer switch), and U (timer start).
Detailed steps for setting up the auto shut-off timer to start counting down at process start or target temp.