EasyManua.ls Logo

Williams WBC40 - Display Slow Down Feature

Williams WBC40
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
Display Slow Down
The purpose of applying a “display slow down” is
to delay the real time temperature being displayed
on the controllers front control interface. This will
avoid rapid uctuations displayed when a door is
opened, or when the controller is “hunting” the
instantaneous temperature. This is achieved by
introducing a thermal mass simulation routine in
the software to simulate a thermal mass inside the
chiller. The parameter “SiM” (default to 3) is used,
and an example being a value of 100 simulates a 0.5
litre (0.1 Gallon) bottle of water.
CONTROLLER

Other manuals for Williams WBC40

Related product manuals