Model(s): J1BCF
Type of Product: Blast Chiller
Refrigerant Fluid(s): R404A / R452A GWP: 3922 / 2140
Blast Chill Cycle: NO
Blast Freeze Cycle: YES
ITEM Symbol Value Unit
Energy Consumption for Chilling Function
E 0.1 kWh/kg
Chilled Full Load Capacity
kg
Energy Consumption for Freezing Function
E 1.052 kWh/kg
Frozen Full Load Capacity
5 kg
Refrigerant Charge 1.8 kg
Blast Chilling Cycle from +65°C to +10°C t min
Blast Chilling Cycle from +65°C to -18°C t 270 min
Contact Details:
Williams Refrigeration, 9 Bryggen Road, North Lynn Industrial Estate, King’s Lynn,
Norfolk. PE30 2HZ
Model(s): WBC70
Type of Product: Blast Chiller
Refrigerant Fluid(s): R452A GWP: 2140
Blast Chill Cycle: YES
Blast Freeze Cycle: NO
ITEM Symbol Value Unit
Energy Consumption for Chilling Function
E 0.163 kWh/kg
Chilled Full Load Capacity
55 kg
Energy Consumption for Freezing Function
E kWh/kg
Frozen Full Load Capacity
kg
Refrigerant Charge 3 kg
Blast Chilling Cycle from +65°C to +10°C t 115 min
Blast Chilling Cycle from +65°C to -18°C t min
Contact Details:
Williams Refrigeration, 9 Bryggen Road, North Lynn Industrial Estate, King’s Lynn,
Norfolk. PE30 2HZ