Maintenance
7-6 WILO EMU 3.0
3 Fill lubricant by means of the opening in the filling plug (D+). Comply with the specified
lubricants and filling quantities.
4 Clean the filling plug (D+), fit with a new sealing ring and screw it in again.
Fig. 7-1: Position of the screw plugs
D+
L
D-

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wilo EMU FA+HC20.1 Series and is the answer not in the manual?

Wilo EMU FA+HC20.1 Series Specifications

General IconGeneral
SeriesEMU FA+HC20.1
CategoryWater Pump
Hydraulic SystemSingle-stage
Protection ClassIP68
Solids PassageUp to 50 mm
Max. Head20 m
Max. Liquid Temperature40 °C
Housing MaterialCast Iron
Motor ProtectionThermal overload protection
Motor CoolingFluid-cooled (Submersible)
ConnectionFlange
Pump TypeSubmersible Pump