  • D
    davisandrewSep 3, 2025
    What to do if my Wilo EMU FA+HC20.1 Water Pump has increased power consumption due to impeller/propeller impeded?
    • L
      Larry RoweSep 3, 2025
      If the impeller/propeller of your Wilo Water Pump is impeded by adhesive material, blockages, or solid matter, resulting in increased current consumption, switch off the machine, secure it against being switched on again, and free the impeller/propeller or clean the suction port.
  • J
    James BrennanSep 18, 2025
    What to do if my Wilo Water Pump has defective sealing chamber cables?
    • A
      Andrew TuckerSep 18, 2025
      If the sealing chamber cables in your Wilo Water Pump are defective, replace the moisture sensors.
  • E
    Elizabeth HoganSep 16, 2025
    What to do if my Wilo EMU FA+HC20.1 has increased leakage when running in new mechanical shaft seals?
    • D
      Donald RodriguezSep 16, 2025
      If your Wilo Water Pump has increased leakage when running in new mechanical shaft seals, change the oil.
  • P
    Pamela MorganSep 14, 2025
    What to do if my Wilo EMU FA+HC20.1 Water Pump has condensation build-up due to lengthy storage?
    • H
      hmcfarlandSep 14, 2025
      If your Wilo Water Pump has condensation build-up due to lengthy storage or temperature fluctuation, operate the machine briefly (max. 5min.) without sealing chamber monitoring.
  • A
    Amanda MillerSep 12, 2025
    What to do if my Wilo Water Pump is installed with mechanical strain?
    • V
      Vernon GainesSep 12, 2025
      If your Wilo Water Pump is installed with mechanical strain, check the installation and use rubber spacers if necessary.
  • A
    Anne WongSep 12, 2025
    What to do if the thermal trigger on the motor protection switch of my Wilo Water Pump is incorrectly set?
    • T
      toddfoxSep 12, 2025
      If the thermal trigger on the motor protection switch of your Wilo Water Pump is incorrectly set, have a specialist compare the setting of the trigger with the technical specifications and adjust it if necessary.
  • D
    Darrell FoxSep 9, 2025
    What to do if my Wilo EMU FA+HC20.1 Water Pump has excessive voltage differences on the three phases?
    • M
      Michael CarterSep 9, 2025
      If there are excessive voltage differences on the three phases of your Wilo Water Pump, have a specialist inspect the connection and the switching system and correct it as necessary.
  • M
    mosesthomasSep 7, 2025
    What to do if my Wilo EMU FA+HC20.1 is operating in two-phase operation?
    • J
      Jonathan LaraSep 7, 2025
      If your Wilo Water Pump is operating in two-phase operation, have a specialist inspect the connection and correct it as necessary.
  • H
    Heidi MedinaSep 5, 2025
    What to do if my Wilo EMU FA+HC20.1 is experiencing excessive decrease in the water table during operation?
    • C
      Colton AdamsSep 6, 2025
      If your Wilo Water Pump is causing an excessive decrease in the water table during operation, check the supply and capacity of the system, and inspect the level control settings and function.
  • B
    Blake GilbertAug 20, 2025
    What to do if my Wilo EMU FA+HC20.1 Water Pump has fuses, the motor protection switch and/or monitoring devices are triggered?
    • Y
      ygardnerAug 21, 2025
      If the fuses, motor protection switch, or monitoring devices are triggered on your Wilo Water Pump: 1. Have a specialist inspect the connection and correct them as necessary. 2. Have the motor protection switch adjusted according to the technical specifications, and reset monitoring equipment. 3. Check that the impeller/propeller runs smoothly. Clean it or free it as necessary.

Wilo EMU FA+HC20.1 Series Specifications

General IconGeneral
SeriesEMU FA+HC20.1
CategoryWater Pump
Hydraulic SystemSingle-stage
Protection ClassIP68
Solids PassageUp to 50 mm
Max. Head20 m
Max. Liquid Temperature40 °C
Housing MaterialCast Iron
Motor ProtectionThermal overload protection
Motor CoolingFluid-cooled (Submersible)
ConnectionFlange
Pump TypeSubmersible Pump