en Maintenance and repair
34 WILO SE 2019-01
3. Spray the pump with clear water from top to bottom. NOTICE!An appropriate dis-
infectant must be used for contaminated pumps! Strictly observe the manufac-
turer’s specifications concerning use!
4. To clean the impeller and the pump interior, guide the water jet inside via the pres-
sure port.
5. Flush all dirt residue onto the floor of the channel.
6. Allow the pump to dry out.
9 Maintenance and repair
DANGER
Danger due to fluids hazardous to health!
If the pump is used in fluids hazardous to health, decontaminate the pump after dis-
mantling and before carrying out any other work! There is a risk of fatal injury! Ob-
serve the specifications in the work regulations! The operator must make sure that
the personnel have received and read the work regulations!
NOTICE
Use only properly functioning lifting equipment!
Use only properly functioning lifting equipment to lift and lower the pump. Ensure
that the pump does not become jammed during lifting and lowering. Do not exceed
the maximum bearing capacity of the lifting equipment! Check that lifting equip-
ment is functioning properly before use!
ƒ Always carry out maintenance tasks in a clean location with good lighting. It must be
possible to position the pump safely and secure it.
ƒ Only carry out maintenance tasks mentioned in these installation and operating in-
structions.
ƒ Wear the following protective equipment while performing maintenance tasks:
Safety goggles
Safety shoes
Safety gloves
9.1 Personnel qualifications
ƒ Electrical work: A qualified electrician must carry out the electrical work.
ƒ Maintenance tasks: The technician must be familiar with the use of operating fluids
and their disposal. In addition, the technician must have basic knowledge of mech-
anical engineering.
9.2 Operator responsibilities
ƒ Provide the necessary protective equipment and make sure that the personnel wears
it.
ƒ Collect operating fluids in suitable tanks and dispose of properly.
ƒ Dispose of protective clothing used in accordance with regulations.
ƒ Use only original parts of the manufacturer. Use of parts other than the original parts
releases the manufacturer from any liability.
ƒ Collect any leakage of fluid and operating fluid immediately and dispose of it ac-
cording to the locally applicable guidelines.
ƒ Provide the tools required.
ƒ If flammable solvents and cleaning agents are used, open flames, naked lights and
smoking are prohibited.
9.3 Labelling of the screw plugs
M
Motor compartment screw plugs
D
Sealing chamber screw plugs
K
Cooling system screw plugs
L
Leakage chamber screw plug
S
Condensation water chamber screw plug
F
Grease nipple screw plug