EasyManua.ls Logo

Wilo MHIL Series - General

Wilo MHIL Series
19 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH
9
1. General
Installation and service by qualified personnel only
1
.1 Applications
Pumps for clear liquids in residential, agricultural, industrial, and other
applications.
- Drawing of water from a well, spring, river, pond, etc. Water should
n
ot be drawn from abyssinian wells (tube, driven well).
1
.2 Technical description
1.2.1 Performance and electrical data
(Table 1)
Permissible temperature range –15 °C to +90 °C
Maximum ambient temperature +40 °C
Maximum permissible working pressure: 10 bar
Mains voltages: 50 Hz (±10%) 60 Hz (±6%)
1 ~ 230 V 1 ~ 220 V
3 ~ 230/400 V 3 ~ 220/380 V
to 254/440 V
Speed (RPM)
50 Hz 60 Hz
2900 RPM 3500 RPM
Mains fuse protection see motor rating plate
Pr
otective system IP 54
Insulation class F
Sound level < 65dB(A)
When ordering spare parts, please give all the information on the
pump/motor rating plate.
Connection diameters
Models
TAPPED PORT ND
SUCTION DISCHARGE
MHIL100 1” - (26-34) 1” - (26-34)
MHIL300 1” - (26-34) 1” - (26-34)
MHIL500 1”
1/4
- (33-42) 1” - (26-34)
MHIL900 1”
1/2
- (40-49) 1”
1/4
- (33-42)
1.2.2 Series specifications
MHIL 3 02 E - 1 - 230 - 50 - 2 / XX/X
Pump
family
Flow rate (m
3
/h)
(2-pole/ 50 Hz)
Number of
stages
E = gaskets EPDM
V =
gaskets VITON
1 = single-phase motor
3 = thr
ee-phase motor
Mains voltage (V)
Frequency (Hz)
2 poles
Manufacturer's key

Related product manuals