INVERTER PUMP MHiKE
MÁY BƠM BIN TN
Installation, Operation, and Maintenance Manual
Cm nang lp đặt, vn hành và bo dưỡng
Before installing and operating the pump, the Safety Instructions must be
thoroughly read for the proper use of the pump.
Đọc k Các ch dn an toàn để s dng máy bơm đúng cách trước khi
lp đặt và vn hành.
Before installation, this manual should be completely studied. / Read this
manual completely before any work on your unit.
Đọc k k Cm nang này trước khi lp đặt và thao tác trên máy bơm.
Keep this manual handy for future reference.
Ct gi Cm nang để thun tin để tham kho sau này.
Product maintenance time table is attached to this manual.
Thi hn bo dưỡng sn phm được nêu trong Cm nang.
ATTENTION: To keep the pump at top efficiency, this manual
should be thoroughly studied.
CHÚ Ý: Xem k C
m nang để đảm bo máy bơm đạt hiu qu ti ưu.

Questions and Answers

  • R
    Richard RodriguezAug 8, 2025
    What to do if Wilo Water Pump has overcurrent?
    • J
      Joseph RosalesAug 8, 2025
      If the Wilo Water Pump experiences overcurrent, it could be due to the impeller reversing. To resolve this, reverse the rotation direction of the impeller. Also, check for any foreign material in the casing, as excessive current to the motor could be the cause.
  • R
    rdavidsonAug 12, 2025
    How to resolve dry running in Wilo MHiKE?
    • O
      oortegaAug 12, 2025
      If your Wilo Water Pump is experiencing dry running, it may be due to air entering the chamber during operation; in this case, the pump should automatically stop. Another cause could be that the water level is lower than the suction pipe's position; try placing the water tank higher than the suction piping. Also, make sure the suction valve is open and check the operating conditions.
  • A
    Ashley HallAug 16, 2025
    Why is the voltage low in my Wilo MHiKE?
    • J
      John OlsonAug 16, 2025
      If your Wilo Water Pump experiences low voltage, it might be because the input voltage is under the rated voltage. When normal power is supplied, the pump automatically restarts. Another possible reason is that an electric machine with high power use operates near the pump. In this case, check the voltage of the power panel.
  • C
    Christopher AndersonAug 21, 2025
    What to do if Wilo MHiKE has overpressure?
    • S
      Selena CunninghamAug 21, 2025
      If your Wilo Water Pump is showing signs of overpressure, it could be due to the valve being rapidly closed. To fix this, check the setting of the maximum pressure and adjust the value.
  • N
    Nicholas SmithAug 26, 2025
    Why is the inverter of my Wilo MHiKE overheating?
    • K
      kathleencookAug 26, 2025
      If your Wilo Water Pump is showing an overtemperature of the inverter, it could be because current in excess of the rated value has been sent for too long. When the temperature goes down, the pump automatically restarts. The ambient temperature may also be too high.
  • T
    timothy25Aug 29, 2025
    What causes overvoltage in Wilo Water Pump?
    • T
      Thomas GarzaAug 29, 2025
      If your Wilo Water Pump is experiencing overvoltage, it means the input voltage is over the rated voltage. When normal power is supplied, the pump automatically restarts.
  • D
    Deborah HudsonSep 3, 2025
    What to do if Wilo Water Pump shows sensor malfunction?
    • L
      Logan PerezSep 3, 2025
      If your Wilo Water Pump displays a sensor malfunction, it could be due to a wrong connection of the sensor. Try rotating the pins of the sensor wire. Another reason could be a disconnected sensor. Check if the connection is disconnected.

Wilo MHiKE Series Specifications

General IconGeneral
Insulation classF
Max. Ambient Temperature+40 °C
Power supply230V, 50Hz
MaterialStainless steel
Frequency50Hz
Power Range0.37 kW to 2.2 kW