SPECIFICATIONS AND PUMP COMPONENTS
QUY CÁCH K THUT VÀ CÁC B PHN MÁY BƠM
MODEL
KIU MÁY
MHiKE-D404A / MHiKE-D802A MHiKE-D405A / MHiKE-D803A
Motor output
Công sut động cơ
1.5kW x 2 1.85kW x 2
Power supply
Ngun đin
1 phase, 220/230V, 50Hz/60Hz
Mt pha, 220/230V, 50Hz/60Hz
Rated capacity
Công sut biu kiến
3.3KVA x 2 4.4KVA X 2
Maximum frequency
Tn s cao nht
~60Hz (RPM : 3,600)
~60Hz (vòng/phút: 3600)
CONNECTING SENSORS WITH THE PUMP
KT NI CM BIN VI MÁY BƠM
MHiKE model is equipped with I/O port which takes part in pressure sensor, external signal input, and communication.
Kiu máy MHiKE được trang b cng tín hiu kết ni cm biến áp sut, đầu vào tín hiu ngoài và truyn thông.
Check the I/O port
Kim tra cng tín hiu
After taking off “Top Cover", check I/O port, voltage free contact, and DIP switch. (Disconnect the pump from the
power source before taking off the top cover.)
Sau khi m “Np trên” kim tra cng tín hiu, tiếp đim không đin áp và công tc DIP. (Ngt đin máy bơm trước khi
m “Np trên”).
The pump is initially set for Pressure Regulation mode, and the pressure sensor is connected.
Máy bơm ban đầ
u được cài đặt chế độ điu tiết áp sut và đã kết ni vi cm biến áp sut.
Image after taking off the top cover: Hình ảnh thực sau khi mở nắp trên
I/O port: Cổng tín hiệu
Voltage free contact: Tiếp điểm không điện áp
DIP switch: Công tắc DIP
Power supply to sensors: Nguồn điện cảm biến
Input sensor Value: Giá trị đầu vào cảm biến
GND: Dây nối đất
Emergency stop: Dừng khẩn cấp
Exterinal signal input: Đầu vào tín hiệu ngoài
Communication: Thông tin liên lạc