TRANSPORTATION AND INSTALLATION
VN CHUYN VÀ LP ĐẶT
WARNING!
CNH BÁO
Install a breaker of electric leakage of under 30mA of
rated sensitivity to prevent electric shock.
Lp cu dao có dòng rò thp hơn 30mA để tránh chp
đin.
Before installation, repair or removal of the
pump, the power supply must be disconnected.
Ngt đin trước khi lp đặt, sa cha hay di
chuyn máy bơm.
Cầu dao
The power cord must not be bent, tied, pulled or twisted by force.
Không dùng lc un cong, vn, kéo hoc xon dây ngun.
Electric leakage, electric shock, or fire can occur.
Có th phát sinh rò đin, chp đin hoc ha hon.
Pay special attention to extensions of the power cord. Any electric
leakage or disconnection in the extension
may cause electric shock.
Chú ý các đon ni dây ngun. Rò đin hoc b đứt các đon ni
có th gây chp đin.
How to extend the power cord:
Cách ni thêm dây ngun:
Peel off the rubber/plastic insulation of the cable as long as the
connection terminal is.
Gt b phn cách đin bng cao su/nha ca dây cáp để to đầu
ni.
Insulate the connection and cover it with rubber tape. Then
tightly cover it over four times with friction tape.
Cách đin cho đầu ni và bc li bng băng keo cao su. Sau đó c
định cht vi 4 ln qun băng keo cách đin
Don’t clasp the power cord in transportation and installation.
Không kéo dây ngun trong quá trình vn chuyn và lp đặt.
The damaged cord may cause electric leakage or shock.
Dây ngun hng có th gây rò đin hoc chp đin.
Use a rated outlet with voltage (220/230V)
fluctuation of less than ±10%.
S dng cm (220/230V) vi mc đin áp
dao động < ±10%.
To prevent electric shock never plug in a
power cord under wet conditions.
Để tránh chp đin, không cm dây ngun b
ướt.
Dây nguồn hoặc phích
cắm 220/230V xoay
chiều
CAUTION!
CHÚ Y!
Install the pump where the pump can be
conveniently checked or repaired after
installation.
Lp đặt máy bơm nơi thun tin kim tra
hoc sa cha sau khi lp đặt.
If the space for the pump is narrow, make the
room as described on the figure.
Nếu din tích lp đặt máy bơm hp, to
phòng bơm như hình v.
When the pump is highly likely to suck in dust or foreign material,
install a sand filter.
Khi máy bơm hot động có th hút phi bi hoc tp cht, lp thêm
b lc cát.
Failure to do so may cause a decline in pressure and quantity of
pumped water, and malfunction of the inverter.
Không lp b lc cát có th làm gim áp sut và cht lượng nước
bơm cũng như gây trc trc b biến tn.
Install a stop valve on the suction side and the discharge side of the
pump for easier pump maintenance.
Lp van chn ca hút và ca x ca máy bơm để bo dưỡng máy
bơm d hơn.
Concrete the foundation with cement to avoid pump slant.
Xây nn bê tông để máy bơm không b nghiêng.
Foundation: Nền đất
Concrete: Bê tông
When the power cord is extended, a voltage
drop that keeps the pump from operation may
be caused. Refer to the table for extended
power cord.
Khi ni thêm dây ngun, có th dn đến st áp
khi vn hành máy bơm. Tham kho bng
thông s ni thêm dây ngun.
Length of power cable
Chiu dài dây ngun
nominal dimension of the cable
kích thước danh định dây ngun
shorter than 50m
Ngn hơn 50m
larger than 1.5 mm
2
> 1.5 mm
2
shorter than 200m
Ngn hơn 200m
larger than 2.0 mm
2
> 2.0 mm
2