MAINTENANCE
86037780 EXTRACTOR 12/09/06
4-6
TROUBLESHOOTING CHART
Worn brush bearings
Squealing or grinding sound in brush
housing.
Replace bearings.
Carpet not getting clean Severe soil conditions
Make several passes at right angles to
each other.
Use a pre-spray.
Carpet too wet
Worn spray jet
Replace spray jet which is producing a
fine mist.
Solution filter screen clogged.
Clean solution filter screen located
inside lower tank.
Spray jet clogged.
Clean or replace jet. Do not use a wire
to clean jet. Damaged jet will cause
over-saturation.
Pump not running.
Check for and correct any loose wires.
Repair or replace.
Carpet not getting wet
Faulty solution switch. Replace switch in handle.