8
5.3.1 Setting of nozzle, speed and moving path
5.3.1.1 In general, there will be better cleaning effect under a slower moving speed.
There is less cable twists occur when cleaner moves at bigger curvature radius and below
instruction is helpful for a proper setting.
5.3.1.2 Overlay of the cleaner’s moving paths at different position of the nozzle
Moving at slow speed(Adjust symble of on the nozzle)
Fig. 5-6
Moving at fast speed (Adjust the symble of ●)
Fig.5-7
Operator can select a proper nozzle position for different pools, for example, chose slow speed
0° 15°30°45°60°75°90°
Symble of
0° 15°30°45°60°75°90°
Position of symble ●
Fig. 5-5