6
Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
1) Thermocouple (TC): Class 1,2,3(IEC/EN 60584-2) or Standard / Special(ASTM E230, ANSI MC 96.1)
The greater of ±2.2 ℃ or ±2%
The greater of ±2.2 ℃ or ±0.75%
The greater of ±1.1 ℃ or ±0.4%
The greater of ±1.7 ℃ or ±1%
The greater of ±1.7 ℃ or ±0.5%
The greater of ±1.0 ℃ or ±0.4%
The greater of ±1.5 ℃ or ±0.25%
The greater of ±0.6 ℃ or ±0.1%
The greater of ±1.5 ℃ or ±0.25%
The greater of ±0.6 ℃ or ±0.1%
The greater of ±2.2 ℃ or ±0.75%
The greater of ±1.1 ℃ or ±0.4%
The greater of ±1.0 ℃ or ±1.5%
The greater of ±1.0 ℃ or ±0.75%
The greater of ±0.5 ℃ or ±0.4%
The greater of ±2.2 ℃ or ±0.75%
The greater of ±1.1 ℃ or ±0.4%
*Note.
Each model has different certification types. See “3.3 Temperature sensor types” and look up the
certifications for the applicable type in the table.
2) Resistance thermometer detector (RTD): Class A, B (IEC/EN 60751)
Temperature range of validity (°C)