Operating manual PMF/GMF Page 28 of 37 B0343
c) Connecting the lubricant feeding lines
Make sure that the lines feeding the lubricating point have been cleaned and
enable free flow!
Link the outlets of the pump elements to the lubricant feeding lines. These lines must be
clean and enable free flow. Connect the lubricant feeding lines to the points to be fed only,
when the lubricant emerges from the respective line without air bubbles. Inspect every con-
nector of the lubricant feeding lines for tightness and lubricating points for free lubricant
supply.
Beware that the pump unit can build up a maximum pressure of far beyond 500 bar de-
pending on the ambient conditions!
Warning! If the pump unit has not yet been equipped with pressure relieving
valves at the date of shipment, the lubricant feeding lines are to
be completed with suitable protective elements in order to avoid
overload of both the pump and lubricant feeding lines.
Warning! Pump pressure above the admissible operating pressure of
350 bar may lead to destruction of the installation and health-
hazardous situations!
6.6 Putting out of operation
The pump unit is put out of operation by switching-off and deinstalling from the external
power supply.