A. Operating instructions
Please refer to the technical drawings
on page 2 more information.
Functions
The AD-series are combined units
that will both clean and dehumidify
the indoor air. The air purifying func-
tion is always active as long as the
unit is running. Activate the dehumi-
dication to remove excess moisture.
When dehumidication is active the
compressor starts and the icon is lit.
When set humidity level is reached,
the icon is ashing.
Modes
The unit has 4 different modes;
manual, automatic, quiet or clothes
dry mode (clothes dry mode is only
available when dehumidifying).
Manual mode
Set fan speed manually. Choose
between 4 fan speeds in dehumidi-
cation mode and 5 fan speeds in air
purication mode. If dehumidication
is activated, set desired humidity
level manually.
Quiet mode
The unit works on the lowest fan
speed. Air quality indicator is shut off.
Clothes dry mode
(dehumidication only).
Use this function for the quickest
drying of clothes and laundry. The
unit will work on maximum fan speed
continuously; humidity level and fan
speed cannot be set.
Automatic mode
In air purication mode, the fan
speed is set automatically depending
on the air quality of the room. The air
quality is indicated by the light on the
front of the unit;
• Green: no pollution detected.
Fan works on speed 1.
• Blue: light pollution detected.
Fan works on speed 2.
• Yellow: moderate pollution
detected. Fan works on speed 3.
• Purple: heavy pollution detected.
Fan works on speed 4.
• Red: very heavy pollution detected.
Fan works on speed 5.
If dehumidication is activated the
unit automatically sets fan speed ac-
cording to ambient relative humidity:
• 60% RH or below: dehumidication
stops, fan runs on speed 1
• 60-65% RH: fan runs on speed 2
• 66-70% RH: fan runs on speed 3
• 71% RH or above: fan runs on
speed 4
Set desired humidity level
When set humidity level is reached
the unit stops automatically. Set
humidity level is shown for a few se-
conds in the display. CO means the
unit will run continuously, regardless
of ambient humidity.
Set timer for shut off
Set time for automatic shut off
between 1 and 12 hours. Press the
timer button repeatedly until the timer
display is blank to deactivate. After
set time has passed the unit is shut
off. To restart it, you need to manually
press the Power button.
Select fan speed
There are 4 fan speeds for dehumidi-
cation and 5 fan speeds for air pu-
rication. A higher fan speed means
quicker air cleaning and dehumidi-
cation.
Active ionizer
Press to activate the ionizer for more
efcient air cleaning. The ionizer
gives the air particles a light electrical
charge which enhances the unit’s air
cleaning capacity.
Child lock
Press and hold the child lock button
for 3 seconds to activate or deacti-
vate the child lock. When activated,
all buttons are locked.
Show room temperature
Press and hold the mode button to
display room temperature. When
released, the display will return to
showing ambient humidity level.
B. Security functions
Automatic shut off function
As a security function, the unit au-
tomatically shuts off if no button has
been touched for 12 hours. Press
any button to reset the 12-hour
countdown.
To deactivate this function, press and
hold the timer button and child lock
button simultaneously for 5 seconds.
The water full indicator ashes and
a buzzer is heard when the function
is deactivated. Repeat this action to
reactivate the function.
Compressor protection
(dehumidication only)
When shut off, the compressor has a
3-minute delay function before star-
ting again to protect the compressor.
Shut off at low or high temperature
(dehumidication only)
When the temperature is below 3°C
or above 40°C the unit will automati-
cally stop dehumidifying and only the
fan will run. The unit will restart dehu-
midication when the temperature is
within the range of 5°C to 38°C.
Low humidity function
(dehumidication only)
When ambient humidity level is
30% or lower, the display shows LO
and the compressor shuts off. It will
resume when the ambient humidity
is 32% or above. When the ambient
humidity is above 91% the display
shows HI (the unit will run as normal).
Water overow protection
(dehumidication only)
When the water bucket is full, the unit
stops, the water full icon ashes and
a buzzer is heard. Empty the water
bucket to restart the unit (see the
section about the water bucket)
Over heat protection
(dehumidication only)
When the unit is dehumidifying at
high room temperature and ambient
humidity level, the fan speed may
automatically be increased to prevent
the unit from over heating. The fan
speed will be restored to set value
when the ambient humidity level
decreases.
English