EasyManua.ls Logo

Woodward ESDR 4T User Manual

Woodward ESDR 4T
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
37138C
ESDR 4T
Current Differential Protection Relay
Manual
Manual 37138C

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Woodward ESDR 4T and is the answer not in the manual?

Woodward ESDR 4T Specifications

General IconGeneral
BrandWoodward
ModelESDR 4T
CategoryRelays
LanguageEnglish

Summary

General Information

Electrostatic Discharge Awareness

Wiring

Wiring Diagram

Illustrates the electrical connections for the ESDR 4T relay.

Power Supply

Details the terminal connections for the 24 Vdc power supply.

Measuring Inputs

Describes terminal connections for current transformer inputs.

Discrete Inputs

Explains terminal connections for discrete digital inputs.

Relay Outputs

Details terminal connections for the relay outputs.

Functional Description

Measurement Inputs

Details the six current values used for differential protection.

Differential Current Monitoring

Explains the two-stage monitoring of differential current.

Tripping Characteristic

Defines the tripping and warning thresholds relative to restraint current.

Electrical Restraint

Describes restraint for inrush current and overexcitation.

Self-Monitoring

Covers the unit's operational readiness and self-monitoring features.

Configuration Overview

Introduces parameter entry via front panel buttons.

Inputs and Outputs

Details control inputs and relay functionalities.

Display and Operating Elements

LEDs and Buttons

Describes the front panel LEDs and their functions.

LC-Display

Explains the operation and display modes of the LC-display.

Configuration

Basic Data

Covers language selection and software version display.

Configuration Access

Explains how to protect configuration with a code.

Configuring Relay Functions

Details how to set relay functions (operating/idle current).

Nominal Data

Defines rated current and voltage values for protected objects.

Differential Protection Data

Specifies current transformer primary values and nominal voltages.

Vector Group Settings

Describes settings for transformer vector groups.

Differential Protection Settings

Details enabling/disabling differential protection monitoring.

Tripping Characteristic

Explains adjustment of tripping and warning thresholds.

Electrical Restraint

Describes settings for inrush and overexcitation restraint.

Commissioning

Prerequisite and Pre-Adjustments

Outlines initial connection and adjustment steps.

Testing with Secondary Values

Describes testing using three-phase test equipment.

Primary Value Testing

Details steps for commissioning using primary current.

Testing for Correct Connection

Covers tests for correct phase sequence and CT connections.

Testing with Cyclical Swapping

Explains rotating CT connections to test relay behavior.

Renewed Test with Correct Connection

Describes re-testing after restoring original connections.

Appendix A: Dimensions

Appendix B: Technical Data

Appendix C: List of Parameters

Vector Group List

Provides a detailed list of transformer vector group definitions.

Service Options

Product Service Options

Describes factory options for servicing Woodward equipment.

Returning Equipment for Repair

Provides instructions for returning equipment to Woodward for repair.

Packing Control

Details materials needed for packing a control for return.

Return Authorization Number

Explains the process for obtaining a Return Authorization Number.

Replacement Parts

Lists information required when ordering replacement parts.

Contacting Woodward

Provides contact information for Woodward support.

Engineering Services

Outlines available after-sales engineering support services.

Technical Assistance

Lists information needed for technical assistance calls.

Related product manuals