6 Months or 100 hrs
• Clean fuel tap and fuel tank filter. Replace if necessary.
• Check fittings and fasteners. Replace if necessary.
12 Months or 300 hrs
• Contact a specialized service centre to check the valve clearance.
• Check the fan of the cooling system for damage.
Spark plug inspection
Fig. 2
• Disconnect the spark plug cap, and remove any dirt from around the spark plug
area.
• Remove spark plug (10) with the plug spanner supplied.
• Inspect the base of the spark plug. It should be a tan colour.
• Measure the gap (distance contact point) with a suitable gauge. The gap should be
0,7 - 0,8 mm. Correct the gap, if necessary, by carefully bending the side electrode.
• Replace the spark plug if the electrodes are worn, or if the insulator is cracked or
chipped.
• Install the spark plug carefully, by hand, to avoid cross-threading.
• Tighten the spark plug to the correct torque: 20 Nm.
• Attach the spark plug cap.
Exhaust screen
• Wait for exhaust to cool.
• Exhaust screen may be blocked up with carbon deposits.
• Undo the screw cap and remove the exhaust screen.
• Clean the screen with a wire brush and refit.
• Replace exhaust screen if damaged.
Air filter cleaning
• Remove the air filter cover (9).
• Remove filter element and wash thoroughly in solvent.
• Pour a small amount of oil onto the filter element and gently squeeze out any
excess oil.
• Replace the filter element and air filter cover.
• Be sure the filter cover seals properly all around.
Do not run the engine without the air filter element in place.
Never place a wet filter (with solvent) on the machine.
PGM6003 Ma EN-IRL 1202-15.indd 12 2/15/12 9:35 AM