5Trouble shooting
Trouble shooting
Below we have listed a few probable causes and solutions to which you can refer if
your machine does not function properly.
Basic checks
• Make sure you have plenty of fuel
• Make sure the fuel tap is on
• Make sure the engine-switch is on
• Remove spark plug, connect spark plug lead and earth it to the generator. Pull
starter cord gently and look for a spark. If there is no spark, replace spark plug.
Spark plug is OK, but engine still won’t start
• Check fuel tap filter is clean (make sure there is no spilt fuel present)
• Check fuel line is clear
• Check carburettor is not blocked
Engine will not start
• Clean or replace spark plug
• Check ignition system – if faulty, contact your service centre
• Check compression – if low, contact your service centre
• Check for loose cylinder head – tighten bolts
• Check for damaged cylinder head gasket – replace if necessary