EasyManua.ls Logo

wtw LF 320/SET User Manual

Default Icon
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Bedienungsanleitungen
Instruction Manuals
BA52207/07.95/Pap/LF320-SET-2
LF 320 / SET
Mikroprozessor Konduktometer
Microprocessor Conductivity meter
LF 320
Standard-Leitfähigkeitsmeßzelle
Standard-conductivity cell
TetraCon
325
BA52207de

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the wtw LF 320/SET and is the answer not in the manual?

wtw LF 320/SET Specifications

General IconGeneral
Temperature accuracy±0.1°C
Reference temperature20°C or 25°C
DisplayLCD
Protection classIP67
Salinity measuring range0.0 to 70.0 PSU
Temperature measuring range-5.0 to 105.0 °C
Cell constant0.475
Resolution0.01 µS/cm
Temperature CompensationAutomatic
TDS measuring range0 to 1999 mg/L
Conductivity accuracy±0.5% of value

Summary

LF 320 Instruction Manual

Display

Defines the display elements and their meanings for the LF 320 instrument.

Keyboard

Details the function of each key on the LF 320 instrument's keypad.

Sockets

Identifies the connection socket and its purpose on the LF 320.

Putting into Operation

Guides the user through the initial setup and power-on procedures for the LF 320.

Measurement

Covers the various measurement functions and procedures for the LF 320.

Conductivity Measurement

Explains how to perform conductivity measurements using the LF 320 instrument.

Setting Cell Constant C

Details how to adjust the cell constant for accurate conductivity measurements on the LF 320.

Setting Temperature Function TC

Describes how to configure the temperature compensation function for the LF 320.

Salinity Measurement

Instructions for measuring salinity with the LF 320 conductivity meter.

Measurement of Total Dissolved Solids (TDS)

Procedure for measuring TDS using the LF 320 instrument.

Selecting Reference Temperature

Explains how to choose the reference temperature setting on the LF 320.

Switching Measurement Range

Guides on how to switch between automatic and manual measurement ranges for the LF 320.

Measured Value Memory

Covers the functions for storing, reading, and erasing measured values on the LF 320.

Storage

Details the process of saving measurements to the LF 320's internal memory.

Readout

Explains how to retrieve stored measurements from the LF 320.

Erasure

Instructions for clearing stored data from the LF 320's memory.

Energy Supply

Information on the power source and battery operation for the LF 320.

Battery Operation

Details on how to operate and manage the batteries for the LF 320.

Maintenance / Cleaning

Provides guidance on the maintenance and cleaning procedures for the LF 320.

Maintenance

Information regarding the maintenance requirements of the LF 320.

Cleaning

Instructions for cleaning the LF 320 instrument.

Troubleshooting

Lists common error messages and their solutions for the LF 320.

Technical Data

Presents the technical specifications and parameters for the LF 320.

TetraCon® 325 Conductivity Cell Manual

Construction

Details the physical components and build of the TetraCon® 325 conductivity cell.

Operation / Maintenance

Covers the operational aspects and care for the TetraCon® 325 cell.

Cleaning

Provides methods for cleaning the TetraCon® 325 conductivity cell.

Aging of the Cell

Discusses the lifespan and factors affecting the TetraCon® 325 cell.

Disposal

Guidance on the proper disposal of the TetraCon® 325 conductivity cell.

Plug Arrangement

Illustrates the pinout and configuration of the TetraCon® 325 cell's connector.

Technical Data

Lists the technical specifications for the TetraCon® 325 conductivity cell.

Measuring Cells and Accessories

Conductivity Cells

Lists different types of conductivity cells available for the LF 320 system.

Recommended Accessories

Presents optional accessories recommended for use with the LF 320.

Spares

Lists spare parts and consumables for the LF 320 system.

Related product manuals