pH/Ion meter
Question and Answer IconNeed help?

Do you have a question about the wtw pH/ION 340i and is the answer not in the manual?

wtw pH/ION 340i Specifications

General IconGeneral
Temperature Resolution0.1 °C
Temperature Accuracy±0.1 °C
Measurement ParameterspH, mV, ISE, temperature
pH Resolution0.001 pH
mV Measurement Range± 2000.0 mV
mV Accuracy±0.3 mV
Calibration3-point calibration
DisplayGraphic LCD with backlight
InterfaceRS-232
Power Supply4 x AA batteries
Temperature Measurement Range-5.0 to 105.0 °C

Summary

Accuracy When Going to Press

Warranty

1 Overview

1.1 General Features

Describes the meter's capabilities for pH, ORP, and concentration measurements.

1.2 SETs of Equipment

Explains that the instrument is available as part of individual SETs of equipment.

1.3 Keypad

Details the functions of each key on the instrument's keypad.

1.4 Display

Explains the different elements and information shown on the instrument's display.

1.5 Jack Field

Identifies and describes the functions of the various connection sockets on the instrument.

1.6 Operating Structure

Illustrates the key presses required to select different measuring modes.

2 Safety

2.1 Authorized Use

Defines the intended and authorized applications for the measuring instrument.

2.2 General Safety Instructions

Provides general safety guidelines for the instrument's safe and reliable operation.

3 Commissioning

3.1 Scope of Delivery

Lists all items included in the standard delivery package of the 340i handheld meter.

3.2 Initial Commissioning

Details the steps for setting the date and time and connecting the power supply.

4 Operation

4.1 Switching on the Measuring Instrument

Explains the procedure for powering on the measuring instrument and its initial state.

4.2 pH Value / ORP Voltage

Details how to measure pH values and ORP voltage using the instrument.

4.2.1 General Information

Outlines preparatory activities required before performing pH/ORP measurements.

4.2.2 Measuring the pH Value

Provides step-by-step instructions for accurately measuring the pH of a sample.

4.2.3 Measuring the ORP Voltage

Guides users on how to measure the ORP (Oxidation-Reduction Potential) voltage.

4.3 pH Calibration

Explains the importance, methods, and procedures for calibrating pH electrodes.

4.3.1 AutoCal TEC

Describes the automatic two-point calibration process using WTW technical buffers.

4.3.2 AutoCal DIN

Details the automatic two-point calibration using standard buffer solutions according to DIN 19266.

4.3.3 ConCal

Explains the conventional single or two-point calibration method for pH measurements.

4.4 Ion Concentration

Covers the procedures for measuring ion concentrations using selective electrodes.

4.4.1 General Information

Outlines preparatory activities for ion concentration measurements with ISEs.

4.4.2 Measuring the Ion Concentration

Provides instructions for measuring ion concentration using an ion-selective electrode.

4.4.3 Calibration for Ion Selective Measurements

Explains the calibration process for ion-selective electrodes based on standard solutions.

4.5 Calibration Interval (Int 3)

Describes how to set and manage the calibration reminder interval for the instrument.

4.6 Saving

Explains how to store measured data records in the instrument's internal memory.

4.6.1 Saving Manually

Details the procedure for manually saving individual measured values to memory.

4.6.2 Switching on AutoStore (Int 1)

Explains how to configure automatic data saving at set time intervals.

4.6.3 Outputting the Data Storage

Describes how to display and output stored data records from the instrument's memory.

Outputting the Calibration Data on the Display

How to view the last calibration results directly on the instrument's display.

Outputting the Calibration Protocol on the Interface

How to transmit the detailed calibration protocol to an external interface.

4.6.4 Clearing the Memory

Provides instructions for deleting all stored data records to free up memory.

4.7 Transmitting Data

Covers methods for transferring data from the instrument to external devices.

4.7.1 Data Transmission Interval (Int 2)

Explains how to set an interval for automatic data transmission to an interface.

4.7.2 PC/External Printer (RS232 Interface)

Details how to connect and transmit data to a PC or printer via the RS232 interface.

4.7.3 Remote Control

Describes how to control the instrument remotely from a PC using a communication kit.

4.8 Configuration

Details how to adapt instrument settings like baud rate, display, and intervals.

4.9 Reset

Explains how to reset measurement and configuration parameters to factory defaults.

5 Maintenance, Cleaning, Disposal

5.1 Maintenance

Covers the primary maintenance task: replacing the instrument's batteries.

5.2 Cleaning

Instructs on how to clean the exterior of the measuring instrument.

5.3 Disposal

Provides guidelines for the environmentally sound disposal of the instrument and its batteries.

6 What to do if...

6.1 pH System Messages

Lists pH-related error messages, their causes, and recommended remedies.

6.2 ISE System Messages

Lists Ion Selective Electrode (ISE) related error messages, causes, and remedies.

6.3 General Errors

Covers general error indicators like low battery and instrument non-responsiveness.

7 Technical Data

8 Lists