Setup and Conguration
The SW-515-RX is congured using RS-232 and/or Telnet commands for IP address, Output Resolution, and EDID. Follow these steps to properly congure the
extender based on the system requirement.
Note: The steps and information provided in this QSG are for basic operation of the extender out of the box. Refer to the SW-515-RX API for full conguration
settings.
1. Assign a Static IP Address to ensure proper communication on an IP Network. See Conguring a Static IP Address
2. Set EDIDs to be used at each input of the device. See Conguring Input EDIDs
Communication Settings
The commands listed below can be sent by connecting to either the TX or
RX for RS-232 and the RX only for Ethernet. Each device must be connected
together via HDBaseT in to order to send a command from one device to the
other. The only exception is Conguring a Static IP Address which requires
connection to the RX.
The SW-515-RX contains a web UI that can be accessed by connecting to a
network and entering the IP address. We recommend that the IP address is
changed from default before accessing the web UI for the rst time.
RS-232 and IP Settings
Baud rate: 115200
Data Bits: 8bits
Parity: None
Stop Bits: 1bit
Flow Control: None
Default IP Address 192.168.11.43
Default IP Port 23
Conguring a Static IP Address
By default, the switcher is set to a static IP of 192.168.11.043. We recommend changing this as it shared with other WyreStorm products and may cause
improper communication if left unchanged. Connect to the RX via RS-232 and send the following command to set the IP address.
Conguring Input EDIDs
By default, all inputs are set to an EDID or 1920x1080@60Hz 2CH. However, this can be congured to suit the installation.
Copyright © 2019 WyreStorm Technologies | wyrestorm.com
SW-515-RX Quickstart Guide | 191212
UK: +44 (0) 1793 230 343 | ROW: 844.280.WYRE (9973)
support@wyrestorm.com
3 of 4
SET IPADDR STATIC ip4addr [IP Address] netmask [Netmask]<CR><LF>
Example: SET IPADDR STATIC ip4addr 192.168.11.243 netmask 255.255.255.0 <CR><LF>
Response: IPADDR STATIC ip4addr 192.168.11.243 netmask 255.255.255.0 <CR><LF>
Note: This command can only be sent to the receivers (RX) RS-232 port.
Set Input EDID
SET EDID [Input] [Resolution] [Device]<CR><LF>
Example: SET EDID in1 1 tx<CR><LF>
Response: EDID SET in1 1 tx<CR><LF>
Query Input EDID
GET EDID [Input] [Device]<CR><LF>
Example: GET EDID in1 tx<CR><LF>
Response: EDID GET in1 1 tx<CR><LF>
Input= VGA | DP | TXHDMI | USBC | RXHDMI1 | RXHDMI2
Resolution={Below tables based on connection}
VGA EDID HDMI/USB-C EDIDs
1024x768@60Hz 2CH 1024x768@60Hz 2CH
1280x768@60Hz 1280x720@60Hz
1360x768@60Hz 1360x768@60Hz
1440x900@60Hz 1440x900@60Hz
1600x900@60Hz 1600x900@60Hz
1680x1050@60Hz 1680x1050@60Hz
1920x1080@60Hz 1920x1080@60Hz
1920x1200@60Hz 3840x2160@30Hz