32 Xanbus System Control Panel (SCP) Owner’s Guide
Troubleshooting
W252 Please confirm:
Restore default
settings.
Manual You have selected
the Restore Defaults
command.
Press Enter to restore
default settings or
Func to cancel.
W254 The value failed to
change. Try again.
Manual The setting you are
changing can only
be changed when
the system is in
Standby mode.
Put the system in
Standby mode, change
the setting, then return
the system to
Operating mode.
W255 System clock not
set. Set correct
time.
Manual
On initial startup,
the clock needs to be
set. The system will
not operate correctly
until it is.
Set the clock to the
correct time. See
“Using the Clock
Menu” on page 21.
W256 A device is lost.
Check connection.
Manual The SCP has lost
communications
with another device
on the network.
Check network
connection between
the SCP and the
device.
W257 New device
detected.
Check device
settings.
Manual You have connected
a new device to the
network or
reconnected a
disconnected
device.
Acknowledge the
message and check
that the device is
properly configured.
W258 Device instance
is duplicated.
Manual Two networked
devices of the same
type have the same
instance.
Select a different
instance ID on one of
the devices’ Setup
menu.
Table 1
Warning Reference Table
Warning
number Message Type Cause Action
W501 SCP has fixed a
memory problem,
restored defaults.
Manual The SCP
encountered an
internal memory
problem upon
startup. To remain
operational, the SCP
restored its default
settings.
Acknowledge the
warning and reset
configurable settings
if necessary.
W502 Not reporting;
Info may be
missing.
Manual
Table 1
Warning Reference Table
Warning
number Message Type Cause Action