Xanbus System Control Panel Installation
The Xanbus System Control Panel (SCP) is designed to be wall mounted
and requires no connections other than Xanbus network cables or a
terminator plugged into the back of the unit.
Because you cannot access the SCP network inputs once the unit is
mounted, the Xanbus cables must be routed through the wall and connected
before securing the SCP.
Materials and Tools Required
The following materials and tools are required to complete the installation:
Mounting template (supplied)
Four mounting screws (supplied)
Cable clamps or hardware fasteners
Xanbus network cables or equivalent (CAT 5 or CAT 5e cable with RJ-
45 connectors wired to T568A standard.
Network terminators (supplied)
Phillips head screwdriver
Jigsaw or small keyhole saw
Power drill with 1/8" bit (optional)
Choosing a Location
Choose a location that allows unobstructed access to the SCP screen and
buttons.
The location should be indoors, dry, and free from corrosive or explosive
fumes.
Network Installation
This section describes requirements for installing the SCP as part of a
Xanbus network-managed power system. For the system to function
properly, requirements for network layout and termination must be
followed.
EXPLOSION HAZARD
The SCP is not Ignition Protected. Do not install in areas requiring
Ignition-Protected equipment, such as areas containing gasoline engines,
tanks, or fuel-line fittings.
Failure to follow these instructions will result in death or serious
injury.