XDT User’s Manual
v
Table of Contents
1.0 Overview of the Dewpoint Transmitter model (DT)...........................................................1
2. Sensor and Sampling Techniques..........................................................................................3
2.1 Precautions using the sensor................................................................................................3
2.2 Sensor Technical Specifications..........................................................................................4
2.3 Sensor Installation & Sampling Techniques........................................................................4
2.3.1 In-situ Installation.............................................................................................................5
2.3.2 Extractive Installation.......................................................................................................6
2.4 Mechanical Installation........................................................................................................7
2.5 Troubleshooting unexpected readings .................................................................................8
3. Instrument..............................................................................................................................9
3.1 Precautions using the Dewpoint Transmitter (DT)..............................................................9
3.1.1 Electromagnetic Compatibility Considerations................................................................9
3.2 Instrument Technical Specifications..................................................................................10
3.3 Installation .........................................................................................................................11
3.3.1 Instrument Mechanical Installation ................................................................................11
3.3.1.1 DT-PM (DIN43700) Enclosure Installation ................................................................11
3.3.1.2 DT-NEMA (IP65) Enclosure Installation....................................................................11
3.3.2 Electrical Connections....................................................................................................12
3.3.2.1 Connecting Power........................................................................................................12
3.3.2.1.1 AC Mains Electrical Power Connection...................................................................13
3.3.2.1.2 Low Voltage DC Powered Option - Electrical Power Connection...........................13
3.3.2.2 Sensor Connection.......................................................................................................13
3.3.2.3 Wiring the Alarm Contacts..........................................................................................13
3.3.2.4 Interfacing to the Analog Output.................................................................................14
3.3.2.5 Interfacing to the RS-232 option .................................................................................15
3.4 Operating the Instrument ...................................................................................................15
3.4.1 Starting up.......................................................................................................................15
3.4.2 Display Conventions.......................................................................................................16
3.4.3 Push Buttons ...................................................................................................................16
3.4.4 Operating State ...............................................................................................................17
3.4.4.1 Viewing Dewpoint Mode.............................................................................................17
3.4.4.2 Alarms..........................................................................................................................19
3.4.4.3 Start Calibration...........................................................................................................20
3.4.4.3.1 SpanCheck™ Mode..................................................................................................21
3.4.4.3.2 Single Point Self Calibration, manual or scheduled .................................................22
3.4.4.4 Viewing Serial Number Mode.....................................................................................25
3.4.5 SetUp State .....................................................................................................................25
3.5 Resetable Audio-Visual Alarm Option (NFPA compliant)...............................................28
3.6 Troubleshooting the Instrument.........................................................................................29
3.7 Maintenance.......................................................................................................................31
Glossary ...................................................................................................................................33
Appendix A: Flow Diagram of Operating State User Interface ..............................................37
Appendix B: Flow Diagram of Set-Up State User Interface ...................................................39
Appendix C: Sensor Mechanical .............................................................................................40