TH series Touchscreen User Manual Page 63 of 81 MANUL018R2V1
Change the save tab: save the data in the registers start from PSW400.
Add a button, to control the stop and start of the collection process. The button is related to PSB300.
3. Data export
Realize the data export function by function button. Click in the tool bar.
Add it on the screen, set the button as the following:
Page data:5, show 5 numbers each screen
Total data:10, it can collect 2 screens data
Pick period: 1 second, collect the data
every 1 second.
Control:PSB300, control the ON/OFF of the