EasyManua.ls Logo

XtendLan DT607 Series - Page 5

XtendLan DT607 Series
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-5-
PARTS AND FUNCTIONS
Terminal description
Lock Control Jumper:
To select the lock type.
Motion Detector Connect Port:
To connect external PIR motion detector.
Main Connect Port:
To connect the bus line and the electronic locks.
L1,L2:
Connect to the bus line, no polarity.
PL:
External lock power input, connect to the power positive(power +).
S+:
Lock power(+) output.
S-:
Lock power(-) output, connect to the power(-) input of locks(only when using the door
station to power the locks, if using the external power supply for the locks, the S- will not be
connected).
1 2 3
Lock Control Jumper
PIR Motion Detector
Connect Port
+12V
GND
PIR
L1
L2
PL
S+
S-