Xtralis VESDA-E VEU-A00 Specifications

General IconGeneral
ModelVEU-A00
TypeAspirating Smoke Detector
Number of Sampling Pipes4
Number of Pipes4
Air Sampling TypeAspirating
Sensitivity Range0.005% obs/m to 20% obs/m
Maximum Coverage Area2000 m²
Power Supply24 VDC
Supply Voltage18 to 30 VDC
CommunicationEthernet
Communication InterfaceEthernet
Air Flow MonitoringYes
Relative Humidity10% to 95% (non-condensing)

Summary

Safety, Compliance, and Product Information

General Warnings and Safety

Important safety precautions for installation, configuration, and maintenance to prevent injury or damage.

Regulatory Compliance and Standards

Details FCC, FDA compliance, and regional requirements for air sampling smoke detection.

Product Features and Specifications

Overview of detector features, components, operation, specifications, and dimensions.

Installation and Setup

Pipe Network Design and Installation

Guides on designing and installing the pipe network, including design and installation considerations.

Detector Mounting and Preparation

Covers preparing the detector, mounting methods (bracket, template, inversion), and wiring.

Powering Up and Preliminary Checks

Details the procedure for powering up the detector and performing preliminary system checks.

Configuration and Connectivity

Communication and Connection Methods

Describes establishing communication via USB, Ethernet, WiFi, and VESDAnet, including profile setup.

Detector Configuration Options

Details configuration settings for General, VESDAnet, Ethernet, WiFi, Smoke Thresholds, Airflow, GPI, and Relays.

Security and Access Control

Outlines security levels, authentication, and access control using passwords and PINs.

Commissioning and Maintenance

Commissioning Procedures

Guides through detector commissioning, including AutoLearn processes and smoke tests.

Maintenance Schedule and Tasks

Provides a maintenance schedule and procedures for replacing components and routine checks.

Spare Parts

Lists the detector's field-replaceable internal components and their ordering numbers.

Troubleshooting and Appendices

Troubleshooting Faults

Guides on identifying and resolving fault conditions using the Fault LED and Xtralis VSC software.

Commissioning Forms and Glossary

Provides templates for commissioning, test results, and definitions of document terms.