M
Mr. William Duncan MDAug 16, 2025
Why Xtreme Garage 425-1620 won't close and light flashes?
- SShannon EstradaAug 16, 2025
The photo eye may be obstructed, not properly aligned or installed. To solve this, check the connection and alignment.
Why Xtreme Garage 425-1620 won't close and light flashes?
The photo eye may be obstructed, not properly aligned or installed. To solve this, check the connection and alignment.
What to do if Xtreme Garage 425-1620 does not respond to the transmitter?
Reprogram the transmitter or check the transmitter battery.
Why Xtreme Garage Garage Door Opener stops before reaching full open or close position?
This issue happens because either the travel limit or force is not properly adjusted. Check the adjustment.
What to do if Xtreme Garage Garage Door Opener reverses unintentionally?
Make sure the photo eye safety system is aligned and clear of obstructions. Also, check the door balance. You may also need to re-adjust the force.
What to do if Xtreme Garage 425-1620 door reverses upon touching the floor and the courtesy light flashes?
Decrease the close limit by 1/4 turn until the door stops as intended at the fully closed position.
Why Xtreme Garage 425-1620 courtesy light flashes 5 times and the opener does not start?
The opener motor may be overheating. Wait about 15 minutes and try again.
What to do if Xtreme Garage Garage Door Opener does not close and the indicator on one of the photo eyes flashes?
The photo eye safety system is misaligned or obstructed. Ensure proper alignment.
Why Xtreme Garage Garage Door Opener is working properly but the courtesy light does not turn on?
Replace the light bulb with an A19 incandescent Max.100W bulb.
Why Xtreme Garage 425-1620 Garage Door Opener courtesy light does not turn off?
The logic board may be defective.
Why Xtreme Garage 425-1620 Garage Door Opener hums as the trolley hits the trolley stop bolt in open travel?
Make sure the trolley is towards the trolley stop bolt. Try disconnecting the trolley by using the emergency release and closing the door manually. Relieve the chain tension by loosening both the chain-to-cable connector and the flange nut. Operate the opener so the trolley shaft travels towards the door (trolley should be kept disconnected). Decrease the open travel limit by 2 full turns. Re-tighten the chain until it is 1/4” (6mm) above the base of rail. Repeat the above steps if the trolley still hits the stop bolt.
Brand | Xtreme Garage |
---|---|
Model | 425-1620 |
Category | Garage Door Opener |
Language | English |
How to connect the opener assembly to the installed header bracket.
Performing the safety reverse test to ensure proper obstruction detection.
Verifying the functionality and alignment of the photo eye system.