OPERATION
Be sure lter drain plug is closed.
1. Open manual air relief valve a few turns and open the suction and return valves (when
used). CAUTION: All suction and discharge valves must be open when starting the system.
Failure to do so could cause severe personal injury and/or property damage. Be sure locking knob is secure
(hand tighten--only slight preissure is required).
2. Stand clear of the lter and prime and start the pump, following the manufacturer’s instructions. Air trapped
in the system will automatically vent to the pool and out air relief valve. Close air relief valve as soon as air
is vented.
CLEAN/REPLACE FILTER BALLS
Filtration starts as soon as ow is steady through the lter.
As the lter cartridge removes dirt from the pool water, the
accumulated dirt causes a resistance to ow. As a result,
the gauge pressure will rise and the ow will decrease.
When the pressure rises 7-10 psi (.49-.70 Bar) above the
starting pressure, or when ow decreases below desired
rate, clean or replace the lter cartridge.
STARTING THE FILTER
FILTERING
Removing lter balls
1.Turn off all system circulation pumps and all electric
power on the equipment pad.
2. Set all system valves in a position to prevent water ow
to the lter.
3. Unfasten the clamp on the inlet, take off the hose, drain
the water.
(Note: To assist draining process: open air vent a few turns.)
4.Unscrew and remove locking ring (counter-clockwise
direction).
5.Carefully lift off top cover to gain access to lter ball.
6.Lift out lter balls and clean. Or, replace with clean, Spare
lter balls. (See Cleaning lter balls.)