9
TESTING
Inspection before use
Trial
o Check installation of the whole machine and the pipe connections according to the pipe
connection diagram
o Check the
electric wiring according to the electric wiring diagram; and make sure the Heat Pump is
bonded
o Make sure that the main machine power switch is off
o Check the temperature setting.
o Check the air inlet and outlet.
The user must “Start the Pump before the Machine, And Turn off the Machine before the
Pump”, or the machine will be damaged
The user should start the pump, check for any water leakage of water; set temperature
in the thermostat, and then switch on power supply.
In order to protect the swimming pool heat pump, the machine is equipped with a time delay
starting function, when starting the machine, the blower will run for 3 minutes before the
compressor starts.
If at any time there is an abnormal noise, smell, smoke, electricity leakage, please switch off power
immediately and contact your local dealer.
Attention
o Set temperature control to achieve a comfortable water temperature and to avoid overheating or
over cooling.
o Always install the machine outdoors, while noting the minimal clearances needed for proper operation
and heating. DO NOT place the unit next to shrubs, fences, etc. which can block the air inlet. These
locations deny the unit a continuous source of fresh air which reduces its efficiency and may prevent
adequate heat delivery.
o Never put hands or any objects into outlet of the swimming pool heat pump, and don’t remove the screen
over the fan at any time.
o If at any time there is an abnormal noise, odor, smoke, electricity leakage, please switch off power
immediately and contact your local dealer.
o Do not use or stock combustible gas or liquids such as paint thinners, paint, fuel near or around the heat
pump.
o As with all pool heat pumps, you are advised to use a pool cover at night and when the pool is not in
use.
o The heat pump should be installed within 10m of the pool to minimize heat loss in the underground
pipes.
Safety
Please keep the main power supply switch out of reach from children.
o If there is a power outage while the machine is in operation, the heat pump will
start up automatically
when power is restored.
o Please switch off the main power supply during lightening storms to prevent any damage to the unit.
o If the machine is stopped for a long time, please cut off the power supply and drain water of the machine
by opening the tap of inlet pipe. If the unit is stopped for a long period of time or for winterizing, the unit
must be drained of all its water. You will need to disconnect the IN and OUT water connections. Then the
unit must be tilted or blown out with air until all water is out.