7
P11 Auto mode setting water temperature 50~113°F YES 79°F
P12 Compressor protection Exhaust temperature 185~230°F NO 203°F
P13 Low ambient temperature protection -4~50°F YES 5°F
P14 EEV manual step number 18~94 NO 70
Check system current status
Press “ button
3S to enter check system current status interface.
NO Meaning Range
Remarks
A01 Water temperature -4~210°F
Measured value
A02 Compressor Exhaust temperature -4~257°F
Measured value
A03 Heating coil temperature -4~210°F
Measured value
A04 Return gas temperature -4~210°F
Measured value
A05 Ambient temperature -4~210°F
Measured value
A06 Cooling coil temperature -4~210°F
Measured value
A07
Manual Control for EE valve
18~94
Measured value