• If the surface of the scooter is contaminated with stains, wipe the appearance with soft cloth
dipped in a small amount of water, and then dry the body.
• Do not directly pour a large amount of water on the brake parts, motor and battery box to prevent
internal water ingress from affecting the service life of the scooter parts.
PART 14 Troubleshooting PART 15 Maintenance and Servicing
Fault code
E0
E1
E2
E3
E4
E5
E6
Fault indication
Communication failure
Grip fault
Brake fault
Motor hall fault
Short circuit of motor phase wire
or MOS tube
Controller failure
Battery fault
Troubleshooting
Check the wires between the controller and instrument and
the batteries, and replace the batteries of the controller and
instrument.
Check the wire or replace the grip.
Check the wire or replace the brake power-off switch.
Check the hall wire or replace the motor.
Check the motor phase wire or replace the motor/controller.
Check the controller wire or replace the controller.
Check the battery connection or replace the battery.
Cleaning Methods
• The tire of this product is pneumatic vacuum tire, with a recommended tire pressure range from
45 to 50 psio. To ensure riding safety, it is recommended to check the tire pressure once a month.
If the tire pressure is insufficient, please inflate the tire in time.
• It is complicated to remove the wheel. If you need to replace the tire, please contact professional
maintenance personnel. Improper self-assembly may lead to component failure or scooter body
instability.
Tire Maintenance
Storage Method
• Do not use alcohol, gasoline, acetone or other corrosive and volatile solvents for cleaning,
which may seriously damage the appearance and internal structure of the scooter.
• Do not wash the scooter with pressure water pipe and water gun or clean it with forcefully.
Attention
• Disconnect the power supply of the scooter and keep it off before cleaning. Fasten the rubber
cap of the charging port tightly; otherwise there may be a risk of electric shock or serious
damage to the electronic components due to internal water ingress.
• Do not contact live parts with wet hands or metal conductors.
Warning
21