Programming
Step 1: Remove the PIR battery insulator
on the back. It will take 30 seconds for the
PIR to initalise (with LED ashing). To allow
calibration, stay away from the detection lens
during this period.
Step 2: Login to the engineer menu on the
control panel. Select “Zone Settings “Zone
Cong. Add Zone on the menu. Press OK
and the LCD of the Control Panel will display
“*Push button on* Device to add”.
Step 3: Press PIR’s Learn button.
Step 4: Then if the Control Panel detects a
signal transmitted from PIR, the Control Panel
will display
“Detected (OK?) PIR sensor”. Press OK to
conrm the learning.
Step 5: Refer to the operation manual (section
Add Zone”) of your Control Panel to complete
the learn-in parameter setup.
Step 6: To nd the best installation location for
the PIR, you will need to make a Walk Test.
Press the “Return button and go back to the
root selection. Select the Testing” Menu, then
select the Walk Test option.
Step 7: Hold the PIR in the desired location
and press the test/learn button. The RSSI signal
strength value will be displayed on the control
panel, varied from 0 ~ 9 (9 indicates the best
signal strength performance). It is suitable for
installation if the RSSI value is 5 or greater.
Device is now ready for mounting.
Mounting
The PIR is suitable for surface or corner
mounting. There are knockout holes in the
base cover to allow xing. Using the holes as a
template to drill mounting points on the wall.
Insert wall plugs and x the base onto the wall.
Put the front cover on the PIR to complete the
mounting process.
It is recommended to install the PIR in the
following locations:
• Inapositionsuchthatanintruderwould
normally move across” the PIR’s eld of
view.
• Between1.9~2.0Mabovegroundforbest
performance.
• Inacornertogivethewidestview.
• Whereitseldofviewwillnotbeobstructed
e.g. by curtains, ornaments etc.
Limitations
• DonotpositionaPIRtolookdirectlyat
a door protected by a Door Contact. This
may cause the Door Contact and the
PIR to transmit at the same
time and cancel each other out.
• DonotexposePIRtodirectsunlight.
• AvoidinstallingthePIRinareaswhere
there are rapid change of temperature, i.e.
air conditioner, heaters, etc.
• Avoidlargeobstaclesinthedetection
area.
• Notpointingdirectlyatsourcesof
heat e.g. res or boilers, and not above
radiators.
• Avoidmovingobjectsinthedetectionarea
i.e. curtain, wall hanging etc.
2M
0 1 2 3 4 5 6 7 8 9 10 11 12 13