Table 2. Parameter Values (Dash Display Software v3.02) (Continued)
Parameter Function Range Default
HYD MTR DEC Sets hydraulic motor
deceleration time
(ramp down).
0.3-10 seconds 0.3
SIDE SHIFT SPEED Adjusts pump motor
speed and current to
Aux prop valve when SS
is requested.
6 to 50% of max speed 19%
4TH AUX IN SPEED Adjusts pump motor
speed and current to
Aux prop valve when 4th
function is requested.
6 to 30% of max speed 10%, depends on 4th
type selected. 3 - No 4th
function.
4TH AUX OUT SPEED Adjusts pump motor
speed and current to
Aux prop valve when 4th
function is requested.
6 to 30% of max speed 10%, depends on 4th
type selected. 3 - No 4th
function.
4TH AUX TYPE Selects 4th function
type.
0 = 4th Function
without Interlock; for a
non-clamping type
attachment. 1 = 4th
Function with Interlock;
for clamping type at-
tachment. 2 = 4th
Function with Push/Pull;
Traction will free coast
during operation. 3 = No
4th Function.
3 - No 4th function.
SERIAL NUMBER Displays truck serial
number.
BATTERY TYPE Flooded or maintenance
free selection.
1 = Flooded, or 2 =
Maint Free
1
BDI MAX ADJ Scale to adjust the
battery voltage which
the truck considers to be
"10" BDI bars.
0 to 9 2
NOTE: Certain lift truck models are not capable of operating at the Max range allowed by the Dash Display. If a parameter
value higher than the truck's ability is entered, the value will revert to the maximum allowed for that lift truck.
Parameters 2200 YRM 1415