Table 2. Parameter Values (Dash Display Software v3.02) (Continued)
Parameter Function Range Default
BDI MIN ADJ Scale to adjust the
battery voltage which
the truck considers to be
"0" BDI bars.
0 to 9 6
BDI ADJ STARTUP Scale to adjust how
many BDI bars are dis-
played immediately on
startup for any given
battery voltage.
0 to 9 7
BDI DELTA RESET Adjusts how much the
battery state-of-charge
must change before the
truck will reset back to
10 bars.
0 to 9 55%
LIFT INTERRUPT Turns lift interrupt ON /
OFF.
0 = off, 1 = on 1
AUD MOTION ALARM This parameter selects
the motion alarm (back-
up horn) activation logic.
0 to 15 1, Reverse Travel
Sounds Alarm
VIS MOTION ALARM Std. option to have lights
turn on when certain
actions occur.
0 to 16 0, No Light
TRAVEL SPD REDUC Enabled by SDO only. XX % of Top Speed Hz 100%, No Reduction
LIFT LIM OVRRID Inhibits lifting when a
certain fork height is
reached, and an opera-
tor command to override
the limit and lift beyond.
Lifting is inhibited when
the limit switch goes
open.
ON / OFF OFF
SERVICE REMINDER ON / OFF selection, will
show “Service Required”
at future hour reading.
Enter Hours. 0 hrs will =
OFF
0 = OFF
TRUCK INSPECTION Enables vehicle
checklist per Operating
Manual.
ON / OFF OFF
SIMULTANEITY Allows a choice between
3 Simultaneity options.
"0" = no simultaneity
"1" = limited simultaneity
"2" = full simultaneity
2
RESTORE DEFAULTS Yes / No; Yes loads
default parameters.
YES / NO NO
NOTE: Certain lift truck models are not capable of operating at the Max range allowed by the Dash Display. If a parameter
value higher than the truck's ability is entered, the value will revert to the maximum allowed for that lift truck.
2200 YRM 1415 Parameters