TILT SPEED FREE
Units are in percent of max speed. Increasing the set-
ting will increase the speed of tilt when forks are be-
low free lift, and the mast prox switch is on.
TILT SPEED MAIN
Units are in percent of max speed. Increasing the set-
ting will increase the speed of tilt when forks are
above free lift (in main lift), and the mast prox switch
is off.
TILT VALV ACC
This parameter sets the tilt valve solenoid opening
(ramp up) time.
TILT VALV DEC
This parameter sets the tilt valve solenoid closing
(ramp down) time.
HYD MTR DEC
This parameter sets the hydraulic motor deceleration
(ramp down) time.
SIDE SHIFT SPEED
Units are in percent of max speed.
4TH AUX IN SPEED
Units are in percent of max speed. This parameter
setting is used to set the hydraulic pump motor speed
and current to aux prop valve when the 4th function
"In" button is depressed for using an attachment, e.g.
clamp or slip-sheet.
4TH AUX OUT SPEED
Units are in percent of max speed. This parameter
setting is used to set the hydraulic pump motor speed
and current to aux prop valve when the 4th function
"Out" button is depressed for using an attachment,
e.g. clamp or slip-sheet.
4TH AUX TYPE
Selects 4th function type.
• 0 = 4th Function without Interlock – Use for a
non-clamping type attachment.
• 1 = 4th Function with Interlock – Use for a
clamping type attachment.
• 2 = 4th
Function with Push/Pull – Use for a push/pull
attachment. Traction will free coast during op-
eration.
• 3 = No 4th Function – This is the default set-
ting.
SERIAL NUMBER
Prompt to load serial number.
BDI MAX ADJ
This parameter setting allows for adjustment to the
battery voltage which the truck considers to be "10"
BDI bars. "0" = lower voltage sensitivity to achieve 10
bars and "9" = higher voltage sensitivity to achieve 10
bars. Factory default values may be different depend-
ing on battery type (flooded vs maintenance-free).
BDI MIN ADJ
This parameter setting allows for adjustment to the
battery voltage which the truck considers to be "0"
BDI bars. "0" = lower voltage sensitivity to achieve 10
bars and "9" = higher voltage sensitivity to achieve 10
bars. Factory default values may be different depend-
ing on battery type (flooded vs maintenance-free).
BDI ADJ STARTUP
This parameter setting allows for adjustment of how
many BDI bars are displayed immediately on startup
for any given battery voltage. "0" = lower voltage for a
given number of bars and "9" = higher voltage for a
given number of bars. Note: This does not affect the
discharge rate of the battery.
BDI DELTA RESET
This parameter setting allows for the adjustment of
how much the battery state-of-charge must change
before the truck will reset back to 10 bars. This pre-
vents a dead battery with only a "surface charge" from
showing 10 bars on the BDI.
BATTERY TYPE
Select either flooded cell or maintenance-free battery
type, depending on type of battery installed to lift
truck.
2200 YRM 1415 Parameter Descriptions
9