Table 1. Parameter Values (Dash Display Software v3.0) (Continued)
Parameter Function Range Default
4TH AUX OUT SPEED Adjusts pump motor
speed and current to
Aux prop valve when 4th
function is requested.
6 to 30% of max speed 10%, depends on 4th
type selected. 3 - No 4th
function.
4TH AUX TYPE Selects 4th function
type.
0 = 4th Function without
Interlock; for a non-
clamping type
attachment. 1 = 4th
Function with Interlock;
for clamping type
attachment. 2 = 4th
Function with Push/Pull;
Traction will free coast
during operation. 3 = No
4th Function.
3 - No 4th function.
SERIAL NUMBER Displays truck serial
number.
BATTERY TYPE Flooded or maintenance
free selection.
1 = Flooded, or 2 =
Maint Free
1
LIFT INTERRUPT Turns lift interrupt on/off. 0 = off, 1 = on 1
AUD MOTION ALARM This parameter selects
the motion alarm (back-
up horn) activation logic.
0 to 15 1, Reverse Travel
Sounds Alarm
VIS MOTION ALARM Std. option to have lights
turn on when certain
actions occur.
0 to 15 0, No Light
TRAVEL SPD REDUC Enabled by SDO only. XX % of Top Speed Hz 100%, No Reduction
LIFT LIM OVRRID Inhibits lifting when a
certain fork height is
reached, and an
operator command to
override the limit and lift
beyond. Lifting is
inhibited when the limit
switch goes open.
ON / OFF OFF
SERVICE REMINDER ON / OFF selection, will
show “Service Required”
at future hour reading.
Enter Hours. 0 hrs will =
OFF
0 = OFF
TRUCK INSPECTION Enables vehicle
checklist per Operating
Manual.
ON / OFF OFF
RESTORE DEFAULTS Yes / No; Yes loads
default parameters.
YES / NO NO
NOTE: Certain lift truck models are not capable of operating at the Max range allowed by the Dash Display. If a parameter
value higher than the truck's ability is entered, the value will revert to the maximum allowed for that lift truck.
Parameters 2200 YRM 1415
4