Maintenance
CALIBRATION
PROCEDURES
GC/GLC030VX, GC/GLC035VX, GC/GLC040SVX [C809];
GLP/GDP16VX, GLP/GDP18VX, GLP/GDP20SVX (GP/GLP/
GDP030VX, GP/GLP/GDP035VX, GP/GLP/GDP040SVX) [C810];
GLC20-35VX (GC/GLC040-070VX, GC/GLC055SVX) [A910, B910];
GLP/GDP20-35VX (GP/GLP/GDP040-070VX) [B875, C875];
GLC40, 45, 55VX; GLC55SVX (GC/GLC080, 100, 120VX; GC/
GLC080, 100VXBCS; GC/GLC120SVX; GC/GLC120VXPRS)
[E818, F818];
GLP/GDP40VX5/VX6; GLP/GDP45SVX5, GLP/ GDP45VX6; GLP/
GDP50-55VX (GP/GLP/GDP080, 090, 100, 110, 120VX)
[F813, G813, H813, J813];
GLP/GDP60VX, GLP/GDP70VX; (GP/GLP/GDP135VX, GP/GLP/
GDP155VX) [C878, D878, E878];
GLC/GDC60VX, GLC/GDC70VX; (GC/GLC/GDC135VX, GC/GLC/
GDC155VX) [C879, D879, E879, F879];
GLP/GDP80VX, GLP/GDP80VX9, GLP/GDP90VX (GLP/GDP170VX,
GLP/GDP175VX36, GLP/GDP190VX) [A909, B909];
GLC030-035VX, GLC040SVX [D809];
GLP/GDP16-18VX, GLP/GDP20SVX (GLP/GDP030-035VX, GLP/
GDP040SVX) [D810];
GLC20-35VX (GC/GLC040-070VX, GC/GLC055SVX) [C910];
GLP/GDP20VX, GLP/GDP25VX, GLP/GDP30VX, GLP/GDP35VX
(GP/GLP/GDP040VX, GP/GLP/GDP050VX, GP/GLP/GDP060VX,
GP/GLP/GDP070VX) [D875]
This manual contains information that is confidential and/or proprietary to Yale Ma-
terials Handling Corporation, its subsidiaries and/or vendors. Copying or distribu-
tion of any sections of this manual marked "Confidential/Proprietary" is prohibited.
PART NO. 524223780 8000 YRM 1134

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Yale GDP100 and is the answer not in the manual?

Yale GDP100 Specifications

General IconGeneral
BrandYale
ModelGDP100
CategoryTest Equipment
LanguageEnglish

Summary

Safety Precautions Maintenance and Repair

ProcCal001 Service Password Entry

ProcCal002 Hydraulic Valve Calibration Warm Up and Air Bleed

ProcCal004 Lift Valve Output Threshold

ProcCal005 Lower Valve Output Threshold

ProcCal006 Tilt Back Valve Output Threshold

ProcCal007 Tilt Forward Valve Output Threshold

ProcCal008 Aux 1 Dir A Valve Output Threshold

ProcCal009 Aux 1 Dir B Valve Output Threshold

ProcCal010 Aux 2 Dir A Valve Output Threshold

ProcCal011 Aux 2 Dir B Valve Output Threshold

ProcCal012 Aux 3 Dir A Valve Output Threshold

ProcCal013 Aux 3 Dir B Valve Output Threshold

ProcCal014 Load Weight Zero Point

ProcCal015 Loaded Weight Calibration

ProcCal016 Transmission Valve Calibration

ProcCal025 Hydraulic Valve Pressure Gage Installation

ProcCal026 Travel Speed Calibration

When to Perform

For trucks with electronic transmissions, when changing tire size.

Why Perform

Ensures accurate travel speed for advanced transmission functions.

How to Perform

Steps to calibrate the travel speed sensor.

Related product manuals