Maintenance
CALIBRATION
PROCEDURES
GC/GLC030VX, GC/GLC035VX, GC/GLC040SVX [C809];
GLP/GDP16VX, GLP/GDP18VX, GLP/GDP20SVX (GP/GLP/
GDP030VX, GP/GLP/GDP035VX, GP/GLP/GDP040SVX) [C810];
GLC20-35VX (GC/GLC040-070VX, GC/GLC055SVX) [A910, B910];
GLP/GDP20-35VX (GP/GLP/GDP040-070VX) [B875, C875];
GLC40, 45, 55VX; GLC55SVX (GC/GLC080, 100, 120VX; GC/
GLC080, 100VXBCS; GC/GLC120SVX; GC/GLC120VXPRS)
[E818, F818];
GLP/GDP40VX5/VX6; GLP/GDP45SVX5, GLP/ GDP45VX6; GLP/
GDP50-55VX (GP/GLP/GDP080, 090, 100, 110, 120VX)
[F813, G813, H813, J813];
GLP/GDP60VX, GLP/GDP70VX; (GP/GLP/GDP135VX, GP/GLP/
GDP155VX) [C878, D878, E878];
GLC/GDC60VX, GLC/GDC70VX; (GC/GLC/GDC135VX, GC/GLC/
GDC155VX) [C879, D879, E879, F879];
GLP/GDP80VX, GLP/GDP80VX9, GLP/GDP90VX (GLP/GDP170VX,
GLP/GDP175VX36, GLP/GDP190VX) [A909, B909];
GLC030-035VX, GLC040SVX [D809];
GLP/GDP16-18VX, GLP/GDP20SVX (GLP/GDP030-035VX, GLP/
GDP040SVX) [D810];
GLC20-35VX (GC/GLC040-070VX, GC/GLC055SVX) [C910];
GLP/GDP20VX, GLP/GDP25VX, GLP/GDP30VX, GLP/GDP35VX
(GP/GLP/GDP040VX, GP/GLP/GDP050VX, GP/GLP/GDP060VX,
GP/GLP/GDP070VX) [D875]
This manual contains information that is confidential and/or proprietary to Yale Ma-
terials Handling Corporation, its subsidiaries and/or vendors. Copying or distribu-
tion of any sections of this manual marked "Confidential/Proprietary" is prohibited.
PART NO. 524223780 8000 YRM 1134

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Yale GDP050VX and is the answer not in the manual?

Yale GDP050VX Specifications

General IconGeneral
BrandYale
ModelGDP050VX
CategoryTest Equipment
LanguageEnglish

Summary

Calibration Procedures

ProcCal001: Service Password Entry

Entry of service password for menu access.

ProcCal002: Hydraulic Valve Calibration Warm Up and Air Bleed

Warm up and bleed hydraulic systems before calibration.

ProcCal003: Save and Exit

Saves calibration results and exits the procedure.

ProcCal004: Lift Valve Output Threshold

Calibrates the lift valve output threshold.

ProcCal005: Lower Valve Output Threshold

Calibrates the lower valve output threshold.

ProcCal006: Tilt Back Valve Output Threshold

Calibrates the tilt back valve output threshold.

ProcCal007: Tilt Forward Valve Output Threshold

Calibrates the tilt forward valve output threshold.

ProcCal008: Aux 1 Dir A Valve Output Threshold

Calibrates the Aux 1 Dir A valve output threshold.

ProcCal009: Aux 1 Dir B Valve Output Threshold

Calibrates the Aux 1 Dir B valve output threshold.

ProcCal010: Aux 2 Dir A Valve Output Threshold

Calibrates the Aux 2 Dir A valve output threshold.

ProcCal011: Aux 2 Dir B Valve Output Threshold

Calibrates the Aux 2 Dir B valve output threshold.

ProcCal012: Aux 3 Dir A Valve Output Threshold

Calibrates the Aux 3 Dir A valve output threshold.

ProcCal013: Aux 3 Dir B Valve Output Threshold

Calibrates the Aux 3 Dir B valve output threshold.

ProcCal014: Load Weight Zero Point

Sets the zero point for load weight calibration.

ProcCal015: Loaded Weight Calibration

Calibrates the loaded weight measurement.

ProcCal016: Transmission Valve Calibration

Calibrates transmission valve settings.

ProcCal016 A: Transmission Valve Calibration-Electronic Extended Function

Electronic extended function for transmission calibration.

ProcCal016 B: Trans. Valve Calibration-Electronic and Electronic Extended Function

Electronic and extended function transmission calibration.

ProcCal019: Mazda LP and Gas Accelerator Pedal Adjustment

Adjusts accelerator pedal for Mazda engines.

ProcCal025: Hydraulic Valve Pressure Gage Installation

Installs pressure gage for hydraulic calibration.

ProcCal026: Travel Speed Calibration

Calibrates travel speed sensor.