EasyManua.ls Logo

Yale GLP030VX

Yale GLP030VX
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Maintenance
CALIBRATION
PROCEDURES
GC/GLC030VX, GC/GLC035VX, GC/GLC040SVX [C809];
GLP/GDP16VX, GLP/GDP18VX, GLP/GDP20SVX (GP/GLP/
GDP030VX, GP/GLP/GDP035VX, GP/GLP/GDP040SVX) [C810];
GLC20-35VX (GC/GLC040-070VX, GC/GLC055SVX) [A910, B910];
GLP/GDP20-35VX (GP/GLP/GDP040-070VX) [B875, C875];
GLC40, 45, 55VX; GLC55SVX (GC/GLC080, 100, 120VX; GC/
GLC080, 100VXBCS; GC/GLC120SVX; GC/GLC120VXPRS)
[E818, F818];
GLP/GDP40VX5/VX6; GLP/GDP45SVX5, GLP/ GDP45VX6; GLP/
GDP50-55VX (GP/GLP/GDP080, 090, 100, 110, 120VX)
[F813, G813, H813, J813];
GLP/GDP60VX, GLP/GDP70VX; (GP/GLP/GDP135VX, GP/GLP/
GDP155VX) [C878, D878, E878];
GLC/GDC60VX, GLC/GDC70VX; (GC/GLC/GDC135VX, GC/GLC/
GDC155VX) [C879, D879, E879, F879];
GLP/GDP80VX, GLP/GDP80VX9, GLP/GDP90VX (GLP/GDP170VX,
GLP/GDP175VX36, GLP/GDP190VX) [A909, B909];
GLC030-035VX, GLC040SVX [D809];
GLP/GDP16-18VX, GLP/GDP20SVX (GLP/GDP030-035VX, GLP/
GDP040SVX) [D810];
GLC20-35VX (GC/GLC040-070VX, GC/GLC055SVX) [C910];
GLP/GDP20VX, GLP/GDP25VX, GLP/GDP30VX, GLP/GDP35VX
(GP/GLP/GDP040VX, GP/GLP/GDP050VX, GP/GLP/GDP060VX,
GP/GLP/GDP070VX) [D875]
This manual contains information that is confidential and/or proprietary to Yale Ma-
terials Handling Corporation, its subsidiaries and/or vendors. Copying or distribu-
tion of any sections of this manual marked "Confidential/Proprietary" is prohibited.
PART NO. 524223780 8000 YRM 1134

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Yale GLP030VX and is the answer not in the manual?

Yale GLP030VX Specifications

General IconGeneral
ModelGLP030VX
CategoryTest Equipment
Output Voltage0 - 30V
Output Current0 - 3A
Power90W
Voltage Resolution10mV
Current Resolution1mA
ProtectionsOVP, OCP, OTP
Ripple and Noise≤1mVrms
InterfaceUSB
DisplayLCD
Operating Temperature0°C to 40°C

Summary

Yale Forklift Calibration Procedures

Calibration Procedures Overview

General description and introductory information for the calibration section of the manual.

Service Password Entry Procedure

Procedure for entering the service password to access calibration and diagnostic menus.

Hydraulic Valve Calibration Warm Up and Air Bleed

Prepares the hydraulic system by warming up fluid and bleeding air before calibration.

Lift Valve Output Threshold Calibration

Calibrates the lift valve's output threshold to ensure proper function and movement.

Load Weight Zero Point Calibration

Sets the zero point for the load weighing system, accounting for carriage assembly weight.

Transmission Valve Calibration

Calibrates the transmission valve pressure to match command current tolerances.

Travel Speed Calibration

Calibrates the travel speed sensor for accurate speed readings and advanced functions.

Safety Precautions for Maintenance and Repair

General Maintenance and Repair Safety Guidelines

Provides essential safety guidelines for performing maintenance and repair tasks on the equipment.

Related product manuals