Maintenance
CALIBRATION
PROCEDURES
GC/GLC030VX, GC/GLC035VX, GC/GLC040SVX [C809];
GLP/GDP16VX, GLP/GDP18VX, GLP/GDP20SVX (GP/GLP/
GDP030VX, GP/GLP/GDP035VX, GP/GLP/GDP040SVX) [C810];
GLC20-35VX (GC/GLC040-070VX, GC/GLC055SVX) [A910, B910];
GLP/GDP20-35VX (GP/GLP/GDP040-070VX) [B875, C875];
GLC40, 45, 55VX; GLC55SVX (GC/GLC080, 100, 120VX; GC/
GLC080, 100VXBCS; GC/GLC120SVX; GC/GLC120VXPRS)
[E818, F818];
GLP/GDP40VX5/VX6; GLP/GDP45SVX5, GLP/ GDP45VX6; GLP/
GDP50-55VX (GP/GLP/GDP080, 090, 100, 110, 120VX)
[F813, G813, H813, J813];
GLP/GDP60VX, GLP/GDP70VX; (GP/GLP/GDP135VX, GP/GLP/
GDP155VX) [C878, D878, E878];
GLC/GDC60VX, GLC/GDC70VX; (GC/GLC/GDC135VX, GC/GLC/
GDC155VX) [C879, D879, E879, F879];
GLP/GDP80VX, GLP/GDP80VX9, GLP/GDP90VX (GLP/GDP170VX,
GLP/GDP175VX36, GLP/GDP190VX) [A909, B909];
GLC030-035VX, GLC040SVX [D809];
GLP/GDP16-18VX, GLP/GDP20SVX (GLP/GDP030-035VX, GLP/
GDP040SVX) [D810];
GLC20-35VX (GC/GLC040-070VX, GC/GLC055SVX) [C910];
GLP/GDP20VX, GLP/GDP25VX, GLP/GDP30VX, GLP/GDP35VX
(GP/GLP/GDP040VX, GP/GLP/GDP050VX, GP/GLP/GDP060VX,
GP/GLP/GDP070VX) [D875]
This manual contains information that is confidential and/or proprietary to Yale Ma-
terials Handling Corporation, its subsidiaries and/or vendors. Copying or distribu-
tion of any sections of this manual marked "Confidential/Proprietary" is prohibited.
PART NO. 524223780 8000 YRM 1134

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Yale GLP35VX and is the answer not in the manual?

Yale GLP35VX Specifications

General IconGeneral
BrandYale
ModelGLP35VX
CategoryTest Equipment
LanguageEnglish

Summary

Safety Precautions Maintenance and Repair

General Safety Guidelines

Essential safety rules for maintenance and repair operations.

Description of Calibration Procedures

Overview of Calibration Process

Explains the purpose and structure of calibration procedures.

Service Password Entry

How to Perform Service Password Entry

Steps for entering the service password to access service menus.

Hydraulic Valve Calibration Warm Up and Air Bleed

Warm Up and Air Bleed Procedure

Steps for warming hydraulic fluid and bleeding air before calibration.

Save and Exit Calibration

How to Save and Exit Calibration

Steps to save calibration results and exit the calibration menu.

Lift Valve Output Threshold Calibration

Calibrating Lift Valve Output Threshold

Procedure to determine the cracking current for the lift valve.

Lower Valve Output Threshold Calibration

Calibrating Lower Valve Output Threshold

Procedure to determine the cracking current for the lower valve.

Tilt Back Valve Output Threshold Calibration

Calibrating Tilt Back Valve Output Threshold

Procedure to determine the cracking current for the tilt back valve.

Transmission Valve Calibration

Performing Transmission Valve Calibration

Calibrates the transmission valve for clutch pack control.

Mazda LP and Gas Accelerator Pedal Adjustment

Adjusting Accelerator Pedal

Adjusts throttle assembly for proper engine and transmission operation.

Travel Speed Calibration

Performing Travel Speed Calibration

Calibrates the travel speed sensor for accurate speed readings.