Table 16. Proc_Cal_014: Load Weight Zero Point (Continued)
A.E-HYD CONTROL LEVERS
1. LIFT/LOWER
DIRECTION LIFT ↓
DIRECTION
LOWER ↑
2.TILT
DIRECTION BACK
DIRECTION FWD
3.*AUX 1 OR AUX
2
DIRECTION A ↑
DIRECTION B ↓
4.*AUX 2 OR AUX
3
DIRECTION A ↑
DIRECTION B ↓
5.*FOURTH
LEVER
6.*THIRD LEVER
7.SEAT ARMREST
*AUX 2 IS IN THE FOURTH LEVER LOCATION EXCEPT AS FOLLOWS: WITH 5 FUNCTION VALVE WITH CLAMPING ATTACHMENT,
AUX 2 IS IN THE THIRD LEVER LOCATION.
2. JOYSTICK
1. TILT BACK 2. AUX 1
DIRECTION A ↑
DIRECTION B ↓
3. LIFT ↓
4. ↑ LOWER
5. AUX 2
DIRECTION A ↑
DIRECTION B ↓
6. TILT FORWARD
7. SEAT ARMREST
Step 1: Press or
Until You See: Main Menu
Calibrations
Step 2: Press * One Time
You Will See: Calibrations
Lift Valve Output
Step 3: Press or
Until You See: Calibrations
Load Weight Set Zero
Step 4: Press * One Time
You Will See: Load Weight Set Zero
Press * with No Load
Action 4: Lower The Empty Forks/Attachment Approximately 51 mm (2 in.), Wait One Second And Immediately
Press * One Time.
Perform Proc_Cal_003: Save and Exit if not performing additional calibration procedures.
8000 YRM 1134 Proc_Cal_014: Load Weight Zero Point