Muffle Furnace
Model
FO 100/200/300/310/410
/510/610/710/810
Instruction Manual
- Third Edition -
Yamato Scientific Co. LTD.,
This paper has been printed on recycled paper.
z Thank you for purchasing "Muffle Furnace, FO
Series" of Yamato Scientific Co., Ltd.
z To use this unit properly, read this "Instruction
Manual" thoroughly before using this unit.
Keep this instruction manual around this unit for
referring at anytime.
WARNING!:
Carefully read and thoroughly understand the
important warning items described in this
manual before using this unit.

Questions and Answers

  • A
    Alvin RamirezAug 1, 2025
    Why does my Yamato Furnace take so long to heat up?
    • T
      Timothy OrtizAug 1, 2025
      If your Yamato Furnace takes too long to reach the desired temperature, it might be due to a faulty temperature sensor, which requires replacement. Alternatively, the issue could stem from an inadequate power supply; ensure you are using an appropriate power source.
  • H
    Heidi CarrAug 7, 2025
    What to do if Yamato Furnace doesn't start?
    • T
      Travis Myers IIAug 7, 2025
      If your Yamato Furnace doesn't start when you turn it on, it could be due to a faulty earth leakage breaker, which should be replaced. Also, check the power source; ensure it's appropriate for the device.
  • R
    Robert BanksAug 13, 2025
    What to do if heater is not turned off in Yamato Furnace?
    • S
      stephanie92Aug 13, 2025
      If the heater in your Yamato Furnace isn't turning off after reaching the preset temperature, the SSR (Solid State Relay) might be faulty and needs to be replaced.
  • C
    Claudia WilsonAug 19, 2025
    Why does the thermal fuse blow out in my Yamato Furnace?
    • E
      ealvarezAug 19, 2025
      If the thermal fuse in your Yamato Furnace keeps blowing out, it might be due to a malfunctioning fan, which needs to be replaced.
  • K
    Karla StevensonAug 26, 2025
    How to fix temperature not rising in Yamato Furnace?
    • B
      brian05Aug 26, 2025
      If the temperature in your Yamato Furnace is not rising, it could be because the heater is disconnected and needs to be replaced.

Summary

Cautions in Using with Safety

Illustrated Symbols Explained

Explains the meaning and usage of various warning, caution, and prohibition symbols found in the manual.

Table of Illustrated Symbols

Provides a comprehensive list and definitions of all safety-related symbols used in the manual.

Understanding WARNING and CAUTION

Details the critical implications and necessary actions associated with 'WARNING!' and 'CAUTION!' statements.

Requirements for Installation

Grounding and Placement Guidelines

Covers essential grounding procedures and criteria for selecting a safe installation location for the unit.

Installation Environment and Power

Specifies restrictions on installation locations and requirements for power supply and cord handling.

Description and Function of Each Part

Main Unit Components

Identifies and describes the physical components of the muffle furnace, including the main body and panels.

Control Panel Functions

Explains the purpose of each button, indicator lamp, and display on the unit's control panel.

Controller Display Characters

Lists and defines the various characters and identifiers shown on the controller's display.

Operation Method

Operation Mode and Function List

Lists and briefly describes all available operation modes for the muffle furnace.

Operation Flowcharts

Illustrates the sequence of key operations for various modes, including fixed temp, timer, and program.

Fixed Temperature Operation

Guides users through setting up and running the furnace at a constant, pre-defined temperature.

Timer Operations (Auto Stop;Start)

Details procedures for Quick Auto Stop, Auto Stop, and Auto Start timer functions.

Program Operation

Explains how to create, register, and run custom temperature programs with multiple steps.

Temperature Rise;Fall Curves

Provides reference graphs showing temperature rise and fall characteristics for specific models.

Other Functions

Overheating Prevention Setting

Describes how to set the overheating prevention device to protect the unit from excessive temperatures.

Calibration Offset and Lock Functions

Explains how to adjust temperature calibration and lock/unlock the control panel.

Handling Precautions

General Safety and Prohibitions

Covers crucial warnings, prohibited substances, and basic safety measures for unit operation.

High Temperature and Environmental Safety

Details precautions for high-temperature operation, material handling, and environmental factors like N2 gas.

Maintenance Method

Daily and Monthly Maintenance

Provides instructions for routine daily inspections and monthly checks of key safety features.

Long Storage and Disposal

Storage and Disposal Procedures

Offers guidance on proper procedures for long-term storage and environmentally sound disposal of the unit.

In the Event of Failure

Safety Device and Error Codes

Lists safety devices, their error notifications, and potential causes and solutions for malfunctions.

Troubleshooting Common Issues

Addresses common problems, their possible causes, and recommended solutions for the unit.

After Service and Warranty

Repair Request and Warranty Information

Details how to request repair services and mentions the minimum retention period for performance parts.

Specification

Model Specifications (FO100-FO410)

Lists the technical specifications for muffle furnace models FO100 through FO410.

Model Specifications (FO510-FO810)

Lists the technical specifications for muffle furnace models FO510 through FO810.

Optional Accessories List

Details available optional accessories, their product codes, and compatibility with the furnace models.

Wiring Diagram

Wiring Diagrams for Models

Illustrates the electrical connections for various muffle furnace models (FO100, FO200/300, etc.).

Replacement Parts Table

Replacement Parts Information

Provides a table of common and model-specific replacement parts, codes, and manufacturers.

Reference

List of Dangerous Substances

Identifies explosive, flammable, and oxidizing substances that must not be used with the unit.

Yamato FO 100 Specifications

General IconGeneral
BrandYamato
ModelFO 100
CategoryFurnace
LanguageEnglish