TROUBLESHOOTING
WARNING:
Before performing any repair work, always ensure that the battery
pack has been removed.
Fault/
malfunction
Cause Remedy
Appliance does not
turn ON
Battery pack discharged? Fully charge the battery pack
Battery pack is not connected
correctly dis charged
place correctly.
Install the battery pack once again.
Safety lock off button has not
been depressed
Check start procedure
1. depress lock off
2. depress switch lever
m/c PCB activated. Restart the device
Pump frozen
Check and allow the appliance to
thaw
Appliance water
pressure too low
Hose damaged or leaks in the
connections.
Change the hose - check the hose
for leaks and repair - securely tighten
the screw connection
Filter blocked
Clean lter on the appliance
Hose is trapped or kinked
Straighten out the hose
Inadequate water supply Check water suply levels
The appliance /water source
height is too large
Lower the appliance - maximum
working height @1.5M- 5ft
Water leaks
O-ring split/broken
Replace the accessory or change
the O-ring
Attachment are not installed
correctly
Remove & re-install the attachment
correctly
Accessories broken Replace accessories
Detergent cannot
spray out
Speed setting on Low
Select speed setting High
Deposits or restrictions in the
detergent system
Flush with clean water and remove
all debris