WATER-FIRED SINGLE-EFFECT
ABSORPTION CHILLER
This product is a water-fired single-effect absorption unit which provides chilled
water for cooling in central plant type air conditioning systems. WFC-SH model chiller-
heaters also provide hot water for heating in two-pipe central plant type systems. Units
with nominal refrigeration capacities of 10, 20, 30, and 50 tons are complete with
operating and safety controls. The absorption chiller or chiller-heater is energized by a
heat medium (hot water) from a process, cogeneration, solar, or waste heat source
capable of providing a temperature range of 158 203°F (70 95°C).
CONTENTS
GENERAL Page
GENERAL 2
MODEL DESIGNATION 2
ACCESSORIES 2
STANDARD SPECIFICATIONS 3
CONTROL ADJUSTMENTS 4
EQUIPMENT DIMENSIONS 5
TYPICAL SYSTEM DESIGN 7
WIRING DIAGRAMS 8
INSTALLATION
RIGGING AND MOVING 11
LOCATION AND CLEARANCES 13
FOUNDATION 13
LEVELING 14
PIPING 14
Page
CHILLED/HOT WATER PIPING 15
COOLING WATER PIPING 15
HEAT MEDIUM PIPING 16
FREEZE PROTECTION 16
ELECTRICAL 17
HIGH VOLTAGE CONNECTIONS 18
CONTROLLING PUMPS AND
VALVES 18
COOLING TOWER FAN CONTROL 19
PUMP SAFETY INTERLOCKS 19
BUILDING MANAGEMENT
SYSTEM INTERFACE 20
REMOTE MONITORING 20
WATER QUALITY 22
INSTALLATION CHECK &
REQUEST FOR STARTUP 22
INSTALLATION INSTRUCTIONS
WFC-SC10, 20, 30, 50
WFC-SH10, 20, 30
Question and Answer IconNeed help?

Do you have a question about the Yazaki Aroace WFC-SC50 and is the answer not in the manual?

Yazaki Aroace WFC-SC50 Specifications

General IconGeneral
BrandYazaki
ModelAroace WFC-SC50
CategoryChiller
LanguageEnglish

Summary

GENERAL

MODEL DESIGNATION

Defines the model naming convention and capacity for Yazaki absorption chillers.

ACCESSORIES

Lists standard and optional accessories provided with or available for the unit.

STANDARD SPECIFICATIONS

Details technical specs like capacity, temperatures, pressures, and dimensions for all models.

EQUIPMENT DIMENSIONS

Provides detailed drawings and measurements of the unit for installation planning.

TYPICAL SYSTEM DESIGN

Illustrates system integration with diagrams for single and multiple module configurations.

WIRING DIAGRAMS

Presents internal and field wiring diagrams crucial for electrical installation and troubleshooting.

INSTALLATION

RIGGING AND MOVING

Procedures and precautions for safely lifting, transporting, and positioning the unit.

LOCATION AND CLEARANCES

Specifies required space around the unit for installation, service, and maintenance access.

FOUNDATION

Guidelines for preparing a level, stable, and non-combustible foundation suitable for the unit's weight.

LEVELING

Instructions for ensuring the unit is perfectly level to guarantee proper fluid distribution and operation.

CHILLED/HOT WATER PIPING

Details for installing the chilled and hot water piping circuits, including connections and valves.

COOLING WATER PIPING

Guidelines for installing the cooling water piping system, including connections, valves, and crossover piping.

HEAT MEDIUM PIPING

Instructions for connecting the heat medium piping system, including bypass valve and flow adjustments.

FREEZE PROTECTION

Methods and precautions for protecting the unit and piping from freezing conditions, especially with glycol.

WATER QUALITY

Recommended water quality limits for chilled, cooling, and heat medium circuits to prevent scaling/corrosion.

INSTALLATION CHECK AND REQUEST FOR STARTUP

Procedures for final installation checks and scheduling the unit startup with an Authorized Service Provider.

Related product manuals