WFC- SC(H)
Chiller
&
Chiller-Heater
2
Installation
WFC-SC(H)10, 20,30 & 50
Version 11-1
Question and Answer IconNeed help?

Do you have a question about the Yazaki WFC-SC Series and is the answer not in the manual?

Yazaki WFC-SC Series Specifications

General IconGeneral
BrandYazaki
ModelWFC-SC Series
CategoryChiller
LanguageEnglish

Summary

General Information

1.1 Precautions

Important safety precautions for installation and handling by qualified personnel.

1.2 Receiving

Inspect the unit for transit damage upon delivery and report any issues.

1.3 Unit Data Plate

Verify model number and voltage against site design from the data plate.

Handling

2.1 Rigging

Guidance on lifting the machine using wire rope and eye-bolts, emphasizing vertical lifting.

2.2 Access Clearances

Planning accessible routes and minimum dimensions for maneuvering the unit.

Place of Installation

3.1 Location

Selecting a suitable indoor or outdoor location considering proximity to other equipment.

3.2 Minimum Maintenance Clearances

Specifies minimum space requirements around the unit for installation and maintenance.

3.3 Foundation

Requirements for a level foundation constructed of non-combustible materials supporting the unit's weight.

3.4 Placement and Leveling

Guidance on positioning, securing mounting bolts, and leveling the chiller-heater.

Piping

4.1 General

General guidelines for installing chilled-hot, cooling, and heat medium water piping.

4.2 Chilled-Hot Water Piping

System design options (open/closed) and valve/thermometer well placement for chilled-hot water.

4.3 Cooling Water Piping

Cooling water temperature limits, mixing valve, flow configuration, and tower placement.

4.4 Heat Medium Piping

Heat medium pipework is closed; care needed with expansion devices and valve types.

Electrical Wiring

5.1 Electrical system diagram

Illustrates the typical electrical system diagram for the absorption machine and associated equipment.

5.2 Electrical connection of auxiliary equipment

Details on wiring auxiliary equipment such as pumps and fans according to diagram.

Junction box electrical wiring

5.3.1 Location of Junction box

Specifies the physical location of the junction box on different WFC-SC(H) models.

5.3.2. Inside of Junction box wiring

Describes the components inside the junction box and terminal markings for wiring.

Remote switching

5.4.1. Location of Control box (CB)

Identifies the location of the Control Box (CB) behind the front panel.

5.4.2. How to wire (remote switch)

Instructions for connecting dry contact signals for remote operation switching.

5.4.3. Position of RUN-REMOTE-STOP Switch

Guidance on setting the RUN-REMOTE-STOP switch to the 'Remote' position.

Condition output signal

5.5.1. How to wiring (condition output signal)

Details on connecting output signals for absorption machine operation and alarm status.

Water Quality

6.1 General

Importance of water quality for chiller-heater operation and warranty validity.

6.2 Water Quality Limits

Table of maximum allowable limits for contaminants in various water circuits.

Ambient temperature

7.1 Winter Shutdown

Procedures for winter shutdown, including draining circuits and using glycol if needed.

Commissioning Request.

8.1 General

Requirement to contact Yazaki distributor for initial test-run and commissioning supervision.

8.2 Start-up Check List

Instructions to copy, complete, and forward the start-up checklist before commissioning.